IMPROPER AIR CIRCULATION - DIAGNOSTIC PROCEDURE

STEP INSPECTION ACTION
1 INSPECT BLOWER UNIT AIR INTAKE SYSTEM 
  • Inspect blower unit air intake links, air intake cranks, and wire clamp.
    • Is there grease on links and cranks?
    • Are links and cranks securely and properly positioned?
    • Is wire clamp free of deformation?
  • Are above items okay?
Yes Go to next step.
No Apply grease or install links and cranks properly and securely, repair or replace wire clamp, then go to Step 6.
2 VERIFY THAT AIR INTAKE WIRE FROM BLOWER UNIT IS POSITIONED SECURELY AND CORRECTLY 
  • Is air intake wire positioned securely and correctly in relation to the blower unit's air intake links?
Yes Go to next step.
No Adjust air intake wire or install securely in correct position, then go to Step 6.
3 INSPECT CLIMATE CONTROL UNIT 
  • Inspect climate control unit.
    • Is air intake wire positioned securely and correctly in relation to the climate control unit's link?
    • Is wire clamp free of deformation?
  • Are above items okay?
Yes Go to next step.
No Install air intake wire securely in correct position, repair or replace wire clamp, then go to Step 6.
4 INSPECT BLOWER UNIT AIR INTAKE DOOR 
  • Is there any foreign material or obstruction in blower unit air intake door?
Yes Remove obstruction, then go to Step 6.
No Go to next step.
5 VERIFY THAT AIR INTAKE DOOR WITHIN BLOWER UNIT IS POSITIONED SECURELY AND PROPERLY 
  • Is blower unit air intake door securely and properly positioned?
Yes Check air intake door for cracks or damage, then go to next step.
No Install air intake door securely in proper position, then go to next step.
6 VERIFY THAT MALFUNCTION SYMPTOM DOES NOT OCCUR AFTER REPAIR 
  • Does air circulate?
Yes Troubleshooting completed. Explain repairs to customer.
No Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.