INSUFFICIENT AIR (OR NO AIR) BLOWN FROM VENTS - DIAGNOSTIC PROCEDURE

STEP INSPECTION ACTION
1 INSPECT AIRFLOW MODE CONTROL SYSTEM, STARTING FROM CLIMATE CONTROL UNIT 
  • When airflow mode control dial is operated, is appropriate resistance felt and can it be moved to its full range?
Yes Go to next step.
No Go to Step 1 of troubleshooting index No.3.
2 CHECK TO SEE IF MALFUNCTION IS IN VENT MODE OR OTHER MODES 
  • Is air discharged when in VENT mode?
Yes Go to Step 5.
No Go to next step.
3 INSPECT VENT 
  • Is vent clogged?
Yes Remove obstruction, then go to Step 9.
No Go to next step.
4 VERIFY THAT DUCT IN DASHBOARD IS INSTALLED 
  • Is duct in dashboard properly installed?
Yes Check duct for clogging, deformity and air leakage, then go to Step 9.
No Install duct securely in the proper position, then go to Step 9.
5 CHECK TO SEE IF MALFUNCTION IS IN HEAT MODE OR DEFROSTER MODE 
  • Is air discharged when in HEAT mode?
Yes Go to next step.
No Check vent for clogging, then go to Step 9.
6 INSPECT DEFROSTER MODE 
  • Is air discharged when in DEFROSTER mode?
Yes Operation is okay. Recheck malfunction symptoms.
No Go to next step.
7 INSPECT VENT 
  • Is vent clogged?
Yes Remove obstruction, then go to Step 9.
No Go to next step.
8 VERIFY THAT DEFROSTER DUCT IS INSTALLED 
  • Is defroster duct properly installed?
Yes Check duct for clogging, deformity, and air leakage, then go to next step.
No Install duct securely in the proper position, then go to next step.
9 VERIFY THAT MALFUNCTION SYMPTOM DOES NOT OCCUR AFTER REPAIR 
  • Is air discharged?
Yes Troubleshooting completed. Explain repairs to customer.
No Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.