LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2002 >> Tribute LX, 4WD >> Repair and Diagnosis >> External Pages >> Different car >> Section 497 (Engine Mechanical [Intake-Air System]) >> Variable Tumble Control System (VTCS) Vacuum Switch Inspection >> Operation Inspection

Operation Inspection

WARNING: This page is about a different car, the 2005 Mazda MX-5 Miata. However, it is still accessible from the selected car via links, so may be relevant.
  1. Disconnect the negative battery cable.
  2. Disconnect the vacuum hose from the VTCS vacuum switch.
  3. Connect a vacuum pump to the VTCS vacuum switch.
  4. Apply vacuum slowly and verify that continuity between the VTCS vacuum switch terminals changes as indicated in the table using an ohmmeter.
    • If not as specified, replace the VTCS vacuum switch.
    • If VTCS vacuum switch is okay but the PID value is out of specification, perform the CIRCUIT OPEN/SHORT INSPECTION .
    Fig 1: VTCS Vacuum Switch PID Value Specification
    G03637804Courtesy of MAZDA MOTORS CORP.
    Connecting Vacuum Pump To VTCS Vacuum Switch

    Vacuum (kPa {mmHg, inHg}) Continuity
    -36.0- -27.8 {-270- -208,-10.6- -8.2} From no continuity to continuity
    -33.9- -27.3 {-254- -204, -10.0- -8.0} From continuity to no continuity