DTC P2504 [BP, BP WITH TC] DIAGNOSTIC PROCEDURE

STEP INSPECTION ACTION
1 VERIFY FREEZE FRAME DATA HAS BEEN RECORDED 
  • Has FREEZE FRAME DATA been recorded?
Yes Go to the next step.
No Record FREEZE FRAME DATA on repair order, then go to the next step.
2 VERIFY RELATED REPAIR INFORMATION AVAILABILITY 
  • Check for related Service Bulletins and/or online repair information availability.
  • Is any related repair information available?
Yes Perform repair or diagnosis according to the available repair information.
  • If the vehicle is not repaired, then go to the next step.
No Go to the next step.
3 INSPECT GENERATOR CONNECTOR FOR POOR CONNECTION 
  • Turn the ignition switch off.
  • Disconnect generator connector.
  • Inspect for poor connection (such as damaged/ pulled-out pins, corrosion).
  • Is there a malfunction?
Yes Repair or replace terminals, then go to Step 8.
No Go to the next step.
4 CLASSIFY GENERATOR MALFUNCTION OR OTHER MALFUNCTION 
  • Turn the ignition switch to the ON position (Engine off).
  • Measure voltage between generator terminal D (harness-side) and body ground.
  • Is voltage B+  ?
Yes Go to the next step.
No Malfunction at generator. Go to Step 7.
5 INSPECT PCM GENERATOR FOR POOR CONNECTOR 
  • Turn the ignition switch off.
  • Disconnect PCM connector.
  • Inspect for poor connection (such as damaged/ pulled-out pins, corrosion).
  • Is there a malfunction?
Yes Repair or replace pins, then go to Step 8.
No Go to the next step.
6 INSPECT GENERATOR CONTROL CIRCUIT FOR SHORT TO POWER 
  • Turn the ignition switch to the ON position (engine OFF).
  • Measure voltage between generator terminal D (harness-side) and body ground.
  • Is voltage B+  ?
Yes Repair or replace harness for short to power, then go to Step 8.
No Go to Step 8.
7 INSPECT GENERATOR CONTROL TERMINAL FOR SHORT TO POWER
  • Measure resistance between generator terminal D (part-side) and body ground.
  • Is voltage B+  ?
Yes Repair or replace generator, then go to the next step.
No Go to the next step.
8 VERIFY TROUBLESHOOTING OF DTC P2504 COMPLETED 
  • Make sure to reconnect all connectors.
  • Clear the DTC from the PCM memory using the WDS or equivalent.
  • Turn the ignition switch off, then start engine.
  • Is the same DTC present?
Yes Replace PCM, then go to the next step.
No Go to the next step.
9 VERIFY AFTER REPAIR PROCEDURE  Yes Go to the applicable DTC inspection.
(See DTC TABLE .)
No Troubleshooting completed.