LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 2002 >> Tribute LX, 4WD >> Repair and Diagnosis >> External Pages >> Different car >> Section 299 (Refrigerant System - HVAC) >> Electronic Leak Detection

Electronic Leak Detection

WARNING: This page is about a different car, the 2003 Mazda Tribute. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION:
  • Good ventilation is necessary in the area where electronic A/C leak testing is to be carried out. If the surrounding air is contaminated with refrigerant gas, the leak detector will indicate this gas all the time. Odors from other chemicals such as antifreeze, diesel fuel, disc brake cleaner, or other cleaning solvents can cause the same problem. A fan, even in a well-ventilated area, is very helpful in removing small traces of contamination from the air that might affect the leak detector. 
NOTE:
  • System pressure should be between 413-551 kPa (60-80 psi) at 24°C (75°F) with the engine off.
Fig 1: Testing Refrigerant System Leakage (1 Of 2)
G01902449Courtesy of MAZDA MOTORS CORP.
  1. Leak test the refrigerant system using the Refrigerant Leak Detector. Follow instructions included with leak detector for handling and operation techniques.
    Fig 2: Testing Refrigerant System Leakage (2 Of 2)
    G01902450Courtesy of MAZDA MOTORS CORP.
  2. If a leak is found, recover the refrigerant and repair the system. For additional information, refer to DISCHARGING AND RECOVERY  .