Miata, Millenia, Protege & Protege5
Connect fused jumper wire between F/P terminal of Data Link Connector (DLC-1) and ground. See Fig 1. Turn ignition switch on for about 5 minutes. Inspect for leakage at fuel hoses, clamps and pipe sealing surfaces. If leaks are found, turn ignition switch off. Release fuel system pressure. See FUEL SYSTEM PRESSURE RELEASE . Repair or replace components as necessary and retest fuel system. If no leaks are found, turn ignition switch off and disconnect fused jumper wire.