Ignition Coil Resistance (MPV)
- Disconnect ignition coil connector. Using ohmmeter, measure primary resistance between ignition coil terminals "A" and "B". See Fig 1
. Resistance should be as specified. See IGNITION COIL RESISTANCE
table. If resistance is not as specified, replace coil.
- Using an ohmmeter, measure secondary resistance between ignition coil terminal "A" and coil tower. See IGNITION COIL RESISTANCE
table. If resistance is not as specified, replace coil.