Fuel Gauge Test: Millenia
- Remove instrument cluster. Connect battery positive voltage to terminal 2G (Black/Yellow wire) terminal of instrument cluster and ground terminal 2I (Brown/Red wire). See Figure . Connect Red wire of Checker (49-0839-285) to terminal 2N (Green/Yellow wire) of instrument cluster. Connect checker Black wire to ground.
- Set checker to specified resistance value. See FUEL GAUGE RESISTANCE (MILLENIA) table. If fuel gauge needle does not rest at specified position for each resistance value setting, replace fuel gauge.
FUEL GAUGE RESISTANCE
| Checker Resistance Setting (Ohms) | Needle Position |
|---|---|
| 88 | Empty |
| 47.5 | Half |
| 7 | Full |