LEMON Manuals: Even more car manuals for everyone
Home >> Mazda >> 1993 >> B2200 DX, Automatic >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Component Testing >> Temperature Gauge Sending Unit

Temperature Gauge Sending Unit

Remove sending unit. Place sending unit in a pan of water with a thermometer. Gradually heat water. Measure resistance between sending unit connector terminal and sending unit body. Replace sending unit if resistance is not as specified. See TEMPERATURE GAUGE SENDING UNIT RESISTANCE  .

TEMPERATURE GAUGE SENDING UNIT RESISTANCE

Application Specification
B2200 49-58 Ohms @ 176°F (80°C)