Self-Diagnostic System: AAS-1
Turn ignition off. Remove combination meter (instrument cluster). Unplug combination meter harness. Unplug 18-wire connector from AAS control unit. Check continuity of Green/Red wire between combination meter and terminal "M" (Green/Red wire) of the control unit. If continuity does not exist, repair wiring as required. If continuity does exist, replace control unit.