Pinpoint Test H: P0601:41, U3000:42, U3000:44, U3000:49
- Normal Operation and Fault Conditions
REFER to: Passive Anti-Theft System (PATS) - System Operation and Component Description .
DTC Fault Trigger Conditions
DTC Description Fault Trigger Condition RFA P0601:41 Internal Control Module Memory Checksum Error: General Checksum Failure Set by the RFA module when fails the internal checksum test RFA U1008:00 Private Communication Network Bus (-) shorted to Bus (+): No Sub Type Information Set by the RFA module when fails the internal LIN test RFA U3000:42 Control Module: General Memory Failure Set by the RFA module when fails the internal RAM test RFA U3000:44 Control Module: Data Memory Failure Set by the RFA module when fails the internal NVM test RFA U3000:49 Control Module: Internal Electronic Failure Set by the RFA module when fails the internal microprocessor test Possible Sources
- RFA module.
- H1 CHECK RFA (REMOTE FUNCTION ACTUATOR) MODULE DIAGNOSTIC TROUBLE CODES (DTCS)
- Using a diagnostic scan tool, clear all RFA module Diagnostic Trouble Codes (DTCs)
- Using a diagnostic scan tool, carry out the RFA module self-test.
Is diagnostic code P0601:14, U3000:42, U3000:44 or U3000:49 present?
Yes CHECK OASIS for any applicable service articles: TSB, GSB, SSM, or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, INSTALL a new RFA module. REFER to: Remote Function Actuator (RFA) Module . No The system is operating correctly at this time.