Pinpoint Test AO: The Adaptive Cruise Control Warning Chime Is Inoperative
- AO1 CHECK THE SEATBELT WARNING CHIME OPERATION
- Ignition OFF.
- Ignition ON.
- Unbuckle the driver seatbelt.
- Monitor the seatbelt warning chime when the ignition is transitioned from OFF to RUN for 6 seconds.
Does the seatbelt warning chime operate for approximately 6 seconds?
Yes GO to AO2 No GO to AO5 - AO2 PERFORM THE IPC (INSTRUMENT PANEL CLUSTER) SELF-TEST
- Using a diagnostic scan tool, perform the IPC self-test.
Are any Diagnostic Trouble Codes (DTCs) recorded?
Yes REFER to DTC Chart: IPC No GO to AO3 - AO3 CHECK THE GWM (GATEWAY MODULE A) DIAGNOSTIC TROUBLE CODES (DTCS)
- Using a diagnostic scan tool, check the GWM Continuous Memory Diagnostic Trouble Codes (CM DTCs).
Are any Diagnostic Trouble Codes (DTCs) recorded?
Yes REFER to: Controller Area Network (CAN) Module Communications Network . No GO to AO4 - AO4 CHECK THE CRUISE CONTROL DISPLAY IN THE MESSAGE CENTER
- Verify the adaptive cruise control display functions in the message center when the adaptive cruise control is in operation.
Does the cruise control display operate in the message center?
Yes DIAGNOSE the cruise control system. REFER to: Cruise Control . No DIAGNOSE the cruise control RTT indicator.GO to Pinpoint Test AD - AO5 CHECK FOR CORRECT IPC (INSTRUMENT PANEL CLUSTER) OPERATION
- Ignition OFF.
- Disconnect and inspect the IPC connector.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the IPC connector. Make sure it seats and latches correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable service articles: TSB, GSB, SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW service article instructions. If no service articles address this concern, INSTALL a new IPC. REFER to: Instrument Panel Cluster (IPC) . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.