Pinpoint Test Dd : U3000:04 Or U3000:46
- DTC Fault Trigger Conditions
DTC Description Fault Trigger Condition IPC U3000:04 Control Module: System Internal Failures Sets in the IPC when the IPC detects an EEPROM failure. IPC U3000:46 Control Module: Calibration/Parameter Memory Failure Sets in the IPC when the IPC detects an EEPROM failure. Possible Sources
- IPC
- DD1 RETRIEVE IPC (INSTRUMENT PANEL CLUSTER) DIAGNOSTIC TROUBLE CODES (DTCS)
- Ignition ON.
- Using a diagnostic scan tool, clear the Diagnostic Trouble Codes (DTCs).
- Wait 10 seconds.
- Using a diagnostic scan tool, perform the IPC self-test.
Is U3000:04 or U3000:46 recorded?
Yes GO to DD2 No The system is operating correctly at this time. - DD2 CHECK FOR CORRECT IPC (INSTRUMENT PANEL CLUSTER) OPERATION
- Ignition OFF.
- Disconnect and inspect the IPC connector.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the IPC connector. Make sure it seats and latches correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable service articles: TSB, GSB, SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, INSTALL a new IPC. REFER to: Instrument Panel Cluster (IPC) . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.