Catalytic Converter LH: Installation
WARNING: This page is about a different variant/trim than selected.
- Clean all exhaust connections before reassembly.
-
NOTE: The following step is only required if the components are being replaced with new items:
Apply anti-seize to thread of sensor, using special tool install the catalyst monitor sensor and the HO2S. Install Special Service Tool: 303-476 (T94P-9472-A) Socket, Exhaust Gas Oxygen Sensor.
Material: Motorcraft® High Temperature Nickel Anti-Seize Lubricant / XL-2
Torque: 35 lb.ft (48 Nm)
-
NOTE: Make sure that new nuts, gasket and the studs are installed.
To install, reverse the removal procedure.
- Check the exhaust system for leaks.