Thermostat Housing: Removal
WARNING: This page is about a different variant/trim than selected.
NOTE:
Removal steps in this procedure may contain installation details.
- Drain the cooling system. Refer to: Engine Cooling System Draining, Vacuum Filling and Bleeding 2.0L EcoBoost . Refer to: Engine Cooling System Draining, Vacuum Filling and Bleeding 2.3L EcoBoost .
-
NOTE: Cover the generator to prevent coolant contamination of the generator.
Completely cover the generator with waterproof plastic. Release the clamp and disconnect the coolant hose. Use the General Equipment: Hose Clamp Remover/Installer
- Release the clamp and disconnect the coolant hose. Use the General Equipment: Hose Clamp Remover/Installer
-
- Remove the bolts and the thermostat housing.
Torque: 89 lb.in (10 Nm)
- Inspect the O-ring seal and replace if necessary.
- Remove the bolts and the thermostat housing.