Pinpoint Test BQ : U0256:00, U0557:80, U0557:81 Or U0557:82: Notes
U0256:00, U0557:80, U0557:81 Or U0557:82
Normal Operation and Fault Conditions
IPC DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| U0256:00 | Lost Communication With Front Controls Interface Module "A": No Sub Type Information | Sets in continuous memory in the IPC if data messages received from the FCIM through the GWM are missing for 5 seconds or longer. |
| U0557:80 | Invalid Data Received From Front Controls Interface Module "A": ISO/SAE Reserved | Sets in continuous memory in the IPC if invalid data messages received from the FCIM are missing for 5 seconds or longer. |
| U0557:81 | Invalid Data Received From Front Controls Interface Module "A": Invalid Serial Data Received | Sets in continuous memory in the IPC if invalid serial data messages received from the FCIM are missing for 5 seconds or longer. |
| U0557:82 | Invalid Data Received From Front Controls Interface Module "A": Alive/Sequence Counter Incorrect/Not Updated | Sets in continuous memory in the IPC if updated data messages received from the FCIM are missing for 5 seconds or longer. |
Possible Sources
- Communication concern
- GWM concern
- FCIM
- IPC concern