LEMON Manuals: Even more car manuals for everyone
Home >> Lincoln >> 2018 >> MKZ Select, FWD >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System (Battery, Mounting And Cables) (Except Hybrid) >> General Procedures >> Battery Disconnect and Connect

Battery Disconnect and Connect

For more information on Ford Color Coded Illustrations refer to OEM COLOR CODING .

Disconnect 

NOTE: Removing the negative battery ground cable at the LH strut tower will not disable the vehicle's electrical system.
NOTE: When the battery (or PCM) is disconnected and connected, some abnormal drive symptoms may occur while the vehicle relearns its adaptive strategy. The charging system set point may also vary. The vehicle may need to be driven to relearn its strategy.
  1. Remove the air cleaner.Refer to: Air Cleaner 2.0L EcoBoost . Refer to: Air Cleaner 3.0L EcoBoost .
    1. Detach the wire harness retainers from the battery tray.
    2. Remove the bolts and the battery hold-down bracket.

      Torque: 89 lb.in (10 Nm)

    GFD262587Courtesy of FORD MOTOR COMPANY
  2. Position the battery.
    GFD262588Courtesy of FORD MOTOR COMPANY
  3. NOTE: When disconnecting the battery cable to interrupt power to the vehicle electrical system, disconnect the battery ground cable only. It is not necessary to disconnect the positive battery cable.

    Loosen the nut and position the negative battery cable.

    Torque: 44 lb.in (5 Nm)

    GFD262589Courtesy of FORD MOTOR COMPANY
    1. Position the positive battery cable cover.
    2. Loosen the nut and position the positive battery cable.

      Torque

      : 44 lb.in (5 Nm)

GFD262590Courtesy of FORD MOTOR COMPANY

Connect 

  1. To install, reverse the removal procedure.