LEMON Manuals: Even more car manuals for everyone
Home >> Lincoln >> 2018 >> MKZ Select, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 765 (Engine Controls - Reference Values (Except Diesel & Hybrid)) >> 3.7L TIVCT Mkt/TAURUS >> Typical Diagnostic Reference Values

Typical Diagnostic Reference Values

WARNING: This page does not describe the selected car, but rather 31 other vehicles, including the 2017 Lincoln Navigator, 2017 Lincoln MKZ, 2017 Lincoln MKX, 2017 Lincoln MKT, and 2017 Lincoln MKC. However, it is still accessible from the selected car via links, so may be relevant.
Inputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
AAT AAT Sensor 3.71/5 (41) 3.71/5 (41) 3.78/4 (39.2) 3.81/3 (37.4) VOLTS/DEG C (DEG F)
APP APP Sensor 0.00 0.00 11.5 6.5 %
APP1 APP Sensor 0.78 0.78 0.98 1.09 VOLTS
APP1(APP_D) APP Sensor 15.68 15.68 19.6 21.56 %
APP2 APP Sensor 0.39 0.39 0.50 0.56 VOLTS
APP2 (APP_E) APP Sensor 7.84 7.84 9.8 10.98 %
APP_MAXDIFF PID 0 0 0 0 %
B+ PID 12.51 13.81 14.24 14.72 VOLTS
BARO PID 13.19/148.79 13.19/148.79 13.19/148.79 13.63/151.53 PSI/Hz
BOO1 BPP Switch OFF ON OFF OFF ON/OFF
BOO2 BPP Switch OFF ON OFF OFF ON/OFF
BRKOVR_ACTION PID 0 0 0 0 km/Miles
BRKOVRD_POSS PID 0 0 0 0 km/Miles
CHT CHT Sensor 3.82/85 (185.0) 0.70/84 (183.20) 0.65/86 (186.80) 0.60/88 (190.40) VOLTS/DEG C (DEG F)
CLRDIST PID 0.00 0.00 0.00 0.00 MILES
DECHOKE PID YES NO NO NO YES/NO
DIST_BRKOVRD PID 0 0 0 0 km/Miles
EONV_RDY PID NOT READY NOT READY NOT READY NOT READY READY/NOT READY
ETC_ACT PID 7.95 1.25 9.03 8.20 Degrees
FPM Fuel Pump Control Module 59.67 (H) 59.67 (H) 59.67 (H) 60.31 (H) %
FTP FTP Sensor 2.66/0.01/0.308 2.53/-0.02/-0.62 1.87/-0.19/-5.27 2.36/-0.06/-1.75 VOLTS/PSI/in-H 2 O
IACKAM2 PID -0.25 -0.13 -0.22 -0.22 NUMERIC VALUE
IAT IAT Sensor 2.87/26 (78.80) 3.58/13 (55.40) 3.74/10 (50.0) 3.88/6 (42.80) VOLTS/DEG C (DEG F)
INJPWR_M PID 12.52 14.11 14.16 14.18 VOLTS
LOAD PID 0.00 (I) 33.33 36.07 68.23 %
LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
LONGFT2 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 %
MAF MAF Sensor 0.00 3.15 7.98 17.75 g/s
MAF MAF Sensor 693.75 1.63k 2.56k 3.46k Hz
MIL_DIS PID 0 0 0 0 Miles
MISFIRE PID NO NO NO NO YES/NO
O2S11_CUR HO2S11 Sensor (I) switching switching switching mA/uA
O2S11_IMPED HO2S11 Sensor 5.00 0.09 0.09 0.09 VOLTS
O2S12 HO2S12 Sensor (I) (D) (D) (D) VOLTS
O2S21_CUR HO2S21 Sensor (I) switching switching switching mA/uA
O2S21_IMPED HO2S21 Sensor 5.00 0.09 0.09 0.09 VOLTS
O2S22 HO2S22 Sensor (I) (D) (D) (D) VOLTS
RPM CKP Sensor 0 604 1125 1530 RPM
SHRTFT1 PID 0 (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SHRTFT2 PID 0 (I) -10 TO +10 -10 TO +10 -10 TO +10 %
SYNC PID NO YES YES YES YES/NO
TP1 ETBTPS 4.09/17.64 4.26/12.54 4.22/15.29 4.19/16.07 VOLTS/%
TP2 ETBTPS 1.23/24.7 0.70/13.72 0.99/19.60 1.03/20.78 VOLTS/%
VCT_EXH _ACT1 PID 0.00 0.00 18.68 49.25 Degrees
VCT_EXH _ACT2 PID 0.00 -0.25 18.98 49.25 Degrees
VCT_INT _ACT1 PID 0.00 0.00 -9.81 -11.37 Degrees
VCT_INT _ACT2 PID 0.00 0.00 -9.81 -11.31 Degrees
VCTSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN/CLOSED LOOP
VSS PID 0 0 48 km/h (30 MPH) 89 km/h (55 MPH) km/h/MPH
Outputs Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
EVAPCP EVAPCP Valve 0.00 34.97 32.15 34.51 %
EVAPCV CANV Valve 0.00 0.00 0.00 0.00 %
EVAPSTA PID NOT RUNNING NOT RUNNING NOT RUNNING NOT RUNNING STATUS
FP Fuel Pump Control Module OFF ON ON ON ON/OFF
FUELSYS PID OPEN LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN/CLOSED LOOP
HTR11 HO2S11 Sensor OFF ON ON ON ON/OFF
HTR12 HO2S12 Sensor OFF ON ON ON ON/OFF
HTR21 HO2S21 Sensor OFF ON ON ON ON/OFF
HTR22 HO2S22 Sensor OFF ON ON ON ON/OFF
MIL PID OFF OFF OFF OFF ON/OFF
O2S11_HTR HO2S11 Sensor 0.00 34.90 31.37 31.76 %
O2S21_HTR HO2S21 Sensor 0.00 34.11 30.98 31.37 %
SPARKADV PID 10.00 10.75 33.25 38.00 DEG
Other Component/PID Only Measured/PID Values Units Measured/PID
KOEO Hot Idle 48 KM/H (30 MPH) 89 KM/H (55 MPH)
VPWR PID 12 13-14 13-14 13-14 VOLTS
VREF PID 5 5 5 5 VOLTS