Home >> Lincoln >> 2018 >> MKZ Select, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 471 (Climate Control System - General Information And Diagnostics) >> Diagnosis And Testing >> Climate Control System >> Pinpoint Tests >> Pinpoint Test D : B1A61:11, B1A61:15, B1A69:11, B1A69:15 >> Pinpoint Test D : B1A61:11, B1A61:15, B1A69:11, B1A69:15

Pinpoint Test D : B1A61:11, B1A61:15, B1A69:11, B1A69:15

WARNING: This page is about a different car, the 2016 Ford Expedition. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may cause damage to the connector.

  1. D1 CHECK THE IN-VEHICLE TEMPERATURE AND HUMIDITY SENSOR CIRCUITS FOR A SHORT TO VOLTAGE

    • Ignition OFF.
    • Disconnect: In-Vehicle Temperature and Humidity Sensor C233.
    • Disconnect: BCM C2280B.
    • Disconnect: HVAC control module - EATC C228A.
    • Disconnect: HVAC control module - EATC C228B.
    • Ignition ON.
    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C233-2
      GFD134422Courtesy of FORD MOTOR COMPANY
      Ground
      C233-3
      GFD134422Courtesy of FORD MOTOR COMPANY
      Ground
      C233-4
      GFD134422Courtesy of FORD MOTOR COMPANY
      Ground
      C233-5
      GFD134422Courtesy of FORD MOTOR COMPANY
      Ground
      C233-6
      GFD134422Courtesy of FORD MOTOR COMPANY
      Ground

    Is any voltage present? 

    Yes  REPAIR the circuit in question.
    No  GO to  D2.
  2. D2 CHECK THE IN-VEHICLE TEMPERATURE AND HUMIDITY SENSOR CIRCUITS FOR A SHORT TO GROUND

    • Ignition OFF.
    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C233-2
      GFD134423Courtesy of FORD MOTOR COMPANY
      Ground
      C233-3
      GFD134423Courtesy of FORD MOTOR COMPANY
      Ground
      C233-4
      GFD134423Courtesy of FORD MOTOR COMPANY
      Ground
      C233-5
      GFD134423Courtesy of FORD MOTOR COMPANY
      Ground
      C233-6
      GFD134423Courtesy of FORD MOTOR COMPANY
      Ground

    Are the resistances greater than 10, 000 ohms? 

    Yes  GO to  D3.
    No  REPAIR the circuit in question.
  3. D3 CHECK THE IN-VEHICLE TEMPERATURE AND HUMIDITY SENSOR CIRCUITS FOR AN OPEN

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C233-1
      GFD134423Courtesy of FORD MOTOR COMPANY
      Ground
      Positive Lead Measurement / Action Negative Lead
      C233-1
      GFD134423Courtesy of FORD MOTOR COMPANY
      C228C-8
      Positive Lead Measurement / Action Negative Lead
      C233-2
      GFD134423Courtesy of FORD MOTOR COMPANY
      C228B-29
      C233-4
      GFD134423Courtesy of FORD MOTOR COMPANY
      C228B-18
      Positive Lead Measurement / Action Negative Lead
      C233-3
      GFD134423Courtesy of FORD MOTOR COMPANY
      C228A-24
      C233-5
      GFD134423Courtesy of FORD MOTOR COMPANY
      C228A-23
      Positive Lead Measurement / Action Negative Lead
      C233-6
      GFD134423Courtesy of FORD MOTOR COMPANY
      C2280B-7

    Are the resistances less than 3 ohms? 

    Yes  GO to  D4.
    No  REPAIR the circuit in question.
  4. D4 CHECK THE IN-VEHICLE TEMPERATURE AND HUMIDITY SENSOR CIRCUITS FOR A SHORT TOGETHER

    Are the resistances greater than 10, 000 ohms? 

    Yes  INSTALL a new in-vehicle temperature and humidity sensor. REFER to Climate Control . TEST the system for normal operation. If the concern is still present, GO to  D5.
    No  REPAIR the circuits in question.
  5. D5 CHECK FOR CORRECT HVAC CONTROL MODULE OPERATION

    • Disconnect and inspect all HVAC control module connectors.
    • Repair:
      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary
    • Reconnect all HVAC control module connectors. Make sure they seat and latch correctly.
    • Operate the system and verify the concern is still present.

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable TSBs. If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no TSB addresses this concern, INSTALL a new HVAC control module. REFER to Climate Control .
    No  The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. ADDRESS the root cause of any connector or pin issues.