Pinpoint Test E : The Roof Opening Panel Does Not Open Or Close: Notes
Refer to Roof Opening Panel for schematic and connector information.
Normal Operation and Fault Conditions
The roof opening panel motor/module receives voltage from the accessory delay relay when the ignition is in the ACC or RUN position. The overhead console switch supplies ground signals to the roof opening panel motor/module to operate the roof opening panel. A failure in the power, ground, or control circuits, an internal failure of the switch or motor/module or a motor/module that has not been initialized all cause the roof opening panel to become inoperative.
Possible Sources
- Fuse(s)
- Wiring, terminals or connectors
- Roof opening panel switch
- Roof opening panel motor/module assembly
- Accessory delay relay
- Roof opening panel motor not initialized
Visual Inspection
- Roof opening panel
- Roof opening panel frame
- Roof opening panel drain hoses
- Roof opening panel lifter assemblies
- Roof opening panel trough
- Roof opening panel air deflector assembly
- Roof opening panel seal
- Roof opening panel shield
Diagnostic Pre-checks
- BCM fuse (80) (20A)
- RJB fuse (37) (5A)
- Circuitry
- Accessory delay relay
- Roof opening panel switch
If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the pinpoint test.