Pinpoint Test F : U3003:17: Notes
WARNING: This page is about a different car, the 2018 Ford Focus. However, it is still accessible from the selected car via links, so may be relevant.
Normal Operation and Fault Conditions
The ABS module, hydraulic pump and solenoid valves require an operating voltage between 10 and 17 volts. The ABS module receives this voltage from the BJB. The ABS module has a single ground circuit located in the engine compartment wiring harness. An overcharging condition in the charging system results in the ABS module setting a DTC. This DTC may also set in the ABS module due to battery charging or vehicle jump starting events.
DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| U3003:17 | Battery Voltage: Circuit Voltage Above Threshold | This DTC sets in continuous memory and on-demand if the voltage supplied to the ABS module is above 17 volts. |
Possible Causes
- Charging system concern
- ABS module