| B1315:11 |
Backlighting (Non Reflective Controls) Illumination Output: Circuit Short to Ground |
GO to Pinpoint Test B . |
| B1315:15 |
Backlighting (Non Reflective Controls) Illumination Output: Circuit Short To Battery or Open |
If all non-networked backlighting is inoperative, GO to Pinpoint Test B . If all non-networked backlighting sources are always on, GO to Pinpoint Test C . |
| U1000:00 |
Solid State Driver Protection Active: No Sub Type Information |
The BCM has temporarily disabled an output because an excessive current draw exists (such as a short to ground). When this DTC is stored in the BCM, the backlighting output driver will be disabled until the cause of the excessive current draw has been corrected and a successful self-test has been performed. ADDRESS all other DTCs first. After the cause of the concern is corrected, CLEAR the DTCs and PERFORM the self-test. |
| U3000:49 |
Control Module: Internal Electronic Failure |
The BCM has permanently disabled an output due to excessive current draw. ADDRESS all other DTCs. After the cause of the concern is corrected, INSTALL a new BCM. REFER to
Multifunction Electronic Modules
. |
| All Other DTCs |
- |
REFER to
Multifunction Electronic Modules
. |