IC Dealer Test Mode
| Display-First Row | Display-Second Row | Description |
|---|---|---|
| GAUGE | TEST | Carries out gauge sweep of all gauges, then displays the present gauge values. |
| SEGMENTS | - | Illuminates all segments in the Vacuum Fluorescent (VF) display area. |
| TELLTALE | TEST | Illuminates all micro-controlled LEDs and automatically scrolls through the message center indicators beginning with the highest priority telltale. |
| PART# | xxxx-xx | Returns all micro-controlled lamps and LEDs to normal operation. Displays alpha numeric part number. |
| ROM CHECKSUM | $xxxxx | Displays hexadecimal value for Read-Only Memory (ROM) level. |
| NVM LEVEL | $xxxxx | Displays hexadecimal ROM level and type as stored in Non-Volatile Memory (NVM). |
| MANUFACTURE | xx-xx-xxxx | Displays final manufacturing test date. |
| B&A CONFIG | xx-xx-xx | Displays hexadecimal coding of second byte of module configuration for as-built data settings. |
| MANUF CONFIG | xxx-xxx-xxx | Displays hexadecimal coding of NVM as-built data settings. |
| CONTINUOUS DTC | $xxxx | Displays a 16-bit DTC in hexadecimal format. DTCs displayed are those detected in continuous operation, not during self-test. |
| VEHICLE SPD | xxx.x | MPH Displays English speed value being input, speedometer indicates present filtered speed. VEHICLE SPD MIS MPH displayed if the input message is missing for greater than 5 seconds. VEHICLE SPD INV MPH displayed if the input message is invalid data. |
| VEHICLE SPD | xxx.x | KM/H Displays metric speed value being input, speedometer indicates present filtered speed. VEHICLE SPD MIS KMH displayed if the input message is missing for greater than 5 seconds. VEHICLE SPD INV KMH displayed if the input message is invalid data. |
| TACHOMETER | xxxx | RPM Displays the tachometer value being input to the IC
. Tachometer indicates present rpm. TACHOMETER MIS RPM displayed if the input message is missing for greater than 5 seconds. TACHOMETER INV RPM displayed if the input message is invalid data. |
| FUEL LEVEL | xxx | INST Displays present fuel level analog/digital ratio input in decimal. 000-009 = short circuit. 10-254 = normal range. |
| 255 = open circuit. | ||
| FUEL LVL % | STATUS xxx | Displays present weighted fuel level percent status in decimal. 000-254 = normal range. 255 = open/short detected for 33 seconds. |
| INSTANT DTE | xxx | MILES Displays instantaneous calculated Distance To Empty (DTE) in miles. |
| FUEL ON/OFF Z | xxx/xxx/xxx | Displays key-on, key-off, and zero speed fuel level values (average of instant). |
| F#S ON/OFF Z | xxx/xxx/xxx | Displays key-on, key-off, and zero speed fuel number of samples (average of instant). |
| COOLANT TEMP | xxx C | Displays last temperature gauge input value from High Speed Controller Area Network (HS-CAN), temperature gauge indicates present filtered temperature. COOLANT TEMP MIS C displayed if input message is missing for greater than 5 seconds. |
| ODOMETER | xxx | COUNTS Displays the odometer input received through HS-CAN
in decimal. ODOMETER MIS COUNTS displayed if input message is missing for greater than 5 seconds. |
| TRIP A ODO | xxx.x | MI Displays the current mileage reading for the trip A odometer stored in Random Access Memory (RAM). |
| TRIP B ODO | xxx.x | MI Displays the current mileage reading for the trip B odometer stored in RAM . |
| BATTERY | xx.x | VOLTS Displays current VBAT analog/digital reading in volts, compensated to yield voltage at the IC connector terminal pin. |
| PRKDETSW | x | Displays current state of the park detect switch position. G = ground |
| O = open | ||
| DIMMING CMD | xx | Displays input status for Smart Junction Box (SJB), 0-254. 0 = dimming off. 255 = invalid data. DIMMING CMD MIS = dimming command not received since Medium Speed Controller Area Network (MS-CAN) initialization or dimming command missing for greater than 5 seconds. |
| DIMMING STEP | xx | Displays current dimming step in decimal. 0-21 for cluster with 21 step dimming or 0-25 for cluster with 25 step dimming. 0 = dimming off. |
| M/C SWITCH | xxx A/D | CNTS Displays current message center switch input analog/digital counts in decimal. Less than 20 = short to ground. 100-190 = INFO button pressed. 400-550 = move on to next. 600-750 = SETUP button pressed. Greater than 830 = no button pressed. |
| LWF OPS OAT | x/x/xxx | Displays the present low washer fluid, oil pressure switch and outside air temperature input analog/digital counts in decimal. |
| COMPASS | xx | Displays present compass input from the compass module in decimal. |
| LAST CHIME | SOUNDED xx | Displays either the last chime sounded by the cluster or the chime that is currently sounding, this excludes the trip reset button press chime. |
| GAUGE | TEST | Returns to the gauge sweep. |