Removal and Installation
WARNING: This page is about a different variant/trim than selected.
- Remove the Air Cleaner (ACL) outlet pipe. For additional information, refer to INTAKE AIR DISTRIBUTION AND FILTERING - 3.5L .
- Disconnect the Camshaft Position (CMP) sensor electrical connector.
- Remove the bolt and the CMP sensor.
- To install, tighten to 10 Nm (89 lb-in).
- To install, reverse the removal procedure.
NOTE:
Lubricate the CMP sensor O-ring seal with clean engine oil.