Refrigerant System Charging Using a R-134a Manifold Gauge Set and Automatic Refrigerant Charging Meter
WARNING: This page is about a different variant/trim than selected.
NOTE:
Ford Motor Company recommends use of a R-134a Refrigerant Management Machine to carry out charging of the refrigerant system. If a R-134a Refrigerant Management Machine is not available, refrigerant system charging may be accomplished using a separate Automatic Refrigerant Charging Meter and R-134a Manifold Gauge Set.
NOTE:
Leaks in refrigerant system service equipment, hoses or gauges can cause a leak that may be misinterpreted as a problem with the vehicle's refrigerant system. It is necessary to leak-test all refrigerant system service equipment, hoses and gauges on a weekly basis to verify that no leaks are present.
- Lubricate the refrigerant system with the correct amount of clean PAG oil (non-hybrid vehicles) or electric A/C compressor oil (hybrid vehicles). For additional information, refer to REFRIGERANT OIL ADDING .
- Assemble the R-134a Manifold Gauge Set, Automatic Refrigerant Charging Meter and R-134a supply tank following the Automatic Refrigerant Charging Meter operating instructions.
- Charge the refrigerant system following the Automatic Refrigerant Charging Meter operating instructions.
- If the refrigerant flow stops before the refrigerant charge is complete, start the engine, select MAX A/C operation and allow the refrigerant charge to complete.
NOTE:
Motorcraft® Electric A/C Compressor Oil only must be used as a refrigerant system lubricant for hybrid vehicles. Addition of any oil other than Motorcraft® Electric A/C Compressor Oil to the hybrid vehicle refrigerant system will damage the electric Air Conditioning (A/C) compressor and contaminate the refrigerant system. For additional information, refer to REFRIGERANT OIL ADDING .