PINPOINT TEST G: DTCs B1B71:11 AND 15
WARNING: This page is about a different variant/trim than selected.
- G1 CHECK THE SENSOR RESISTANCE
- Ignition OFF.
- Disconnect: HVAC Module - Electronic Manual Temperature Control (EMTC) C2357a.
- Disconnect: HVAC Module - Dual Automatic Temperature Control (DATC) C2356a.
- Measure the resistance between HVAC module - EMTC C2357A-6 or HVAC module - DATC C2356A-6, circuit VH406 (VT/BN), harness side and HVAC module - EMTC C2357A-10 or HVAC module - DATC C2356A-10, circuit RH111 (GY/BU), harness side.
- Compare the measurement to the chart and table of the Evaporator Discharge Air Temperature Sensor component test, refer to EVAPORATOR DISCHARGE AIR TEMPERATURE SENSOR .
- Is the resistance within the specified values for the temperatures?
- G2 CHECK CIRCUIT VH406 (VT/BN) FOR A SHORT TO GROUND
- Measure the resistance between HVAC module - EMTC C2357A-6 or HVAC module - DATC C2356A-6, circuit VH406 (VT/BN), harness side and ground.
- Is the resistance greater than 10, 000 ohms?
- Yes: GO to G7.
- No: REPAIR circuit VH406 (VT/BN) for a short to ground. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- G3 CHECK CIRCUIT VH406 (VT/BN) FOR A SHORT TO VOLTAGE
- Ignition ON.
- Measure the voltage between ground and HVAC module - EMTC C2357A-6 or HVAC module - DATC C2356A-6, circuit VH406 (VT/BN), harness side and ground.
- Is any voltage present?
- Yes: REPAIR circuit VH406 (VT/BN) for a short to voltage. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- No: GO to G7.
- G4 CHECK CIRCUIT VH406 (VT/BN) FOR A SHORT TO CIRCUIT RH111 (GY/BU) NOTE: Instrument panel removal is required to disconnect the sensor. Before carrying out this test step, visually inspect the wiring between the HVAC module and sensor for shorts. If no damage is visually evident, proceed with the test.
- Ignition OFF.
- Disconnect: Evaporator Discharge Air Temperature Sensor C2295.
- Measure the resistance between HVAC module - EMTC C2357A-6 or HVAC module - DATC C2356A-6, circuit VH406 (VT/BN), harness side and HVAC module - EMTC C2357A-10 or HVAC module - DATC C2356A-10, circuit RH111 (GY/BU), harness side.
- Is the resistance greater than 10, 000 ohms?
- Yes: INSTALL a new evaporator discharge air temperature sensor. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- No: REPAIR circuit VH406 (VT/BN) for a short to circuit RH111 (GY/BU). CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- G5 CHECK CIRCUITS VH406 (VT/BN) FOR AN OPEN NOTE: Instrument panel removal is required to disconnect the sensor. Before carrying out this test step, visually inspect the wiring between the HVAC module and sensor for opens. If no damage is visually evident, proceed with the test.
- Ignition OFF.
- Disconnect: Evaporator Discharge Air Temperature Sensor C2295.
- Measure the resistance between HVAC module - EMTC C2357A-6 or HVAC module - DATC C2356A-6, circuit VH406 (VT/BN), harness side and inline (EMTC) C211-13 or (DATC) inline C213-13, circuit VH406 (VT/BN), instrument panel harness side.
- Measure the resistance between inline (EMTC) C211-13 or (DATC) inline C213-13, circuit VH406 (VT/BN), HVAC case harness side and evaporator discharge air temperature sensor C2295-1, circuit VH406 (VT/BN), harness side.
- Is the resistance less than 5 ohms?
- Yes: GO to G6.
- No: REPAIR circuit VH406 (VT/BN) for an open. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- G6 CHECK CIRCUITS RH111 (GY/BU) FOR AN OPEN
- Measure the resistance between HVAC module - EMTC C2357A-10 or HVAC module - DATC C2356A-10, circuit RH111 (GY/BU), harness side and inline (EMTC) C211-15 or (DATC) inline C213-15, circuit RH111 (GY/BU), instrument panel harness side.
- Measure the resistance between inline (EMTC) C211-15 or (DATC) inline C213-15, circuit RH111 (GY/BU), HVAC case harness side and evaporator discharge air temperature sensor C2295-2, circuit RH111 (GY/BU), harness side.
- Is the resistance less than 5 ohms?
- Yes: INSTALL a new evaporator discharge air temperature sensor. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- No: REPAIR circuit RH111 (GY/BU) for an open. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- G7 CHECK THE MODULE CONNECTION
- Inspect the module connectors for:
- corrosion.
- pushed-out terminals.
- damaged terminals.
- Connect and correctly seat all the HVAC module connectors.
- Clear the DTCs.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes: INSTALL a new HVAC module. REFER to CLIMATE CONTROL . TEST the system for normal operation.
- No: The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- Inspect the module connectors for: