PINPOINT TEST E: DTCs B1A68:11 AND 15
WARNING: This page is about a different variant/trim than selected.
- E1 CHECK THE SENSOR RESISTANCE
- Ignition OFF.
- Disconnect: Ambient Air Temperature Sensor C132.
- Measure the resistance between the ambient air temperature sensor C132 terminals and compare to the table below.
Ambient Temperature Resistance -40°C (-40°F) 832, 519-1, 017, 523 ohms -15°C (5°F) 199, 325-220, 307 ohms 0°C (32°F) 91, 058-100, 644 ohms 15°C (59°F) 44, 435-49, 113 ohms 25°C (77°F) 28, 500-31, 500 ohms 35°C (95°F) 18, 730-20, 701 ohms 60°C (140°F) 7, 171-7, 925 ohms 85°C (185°F) 3, 110-3, 438 ohms - Is the resistance within the specified values for the temperatures?
- Yes: GO to E2.
- No: INSTALL a new ambient air temperature sensor. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- E2 CHECK THE SENSOR OUTPUT VOLTAGE
- Ignition ON.
- Measure the voltage between ambient air temperature sensor C132-1, circuit VH407 (YE/GN), harness side and C132-2, circuit RH111 (GY/BU), harness side.
- Is the voltage between 4.7 and 5.1 volts?
- E3 CHECK CIRCUIT VH407 (YE/GN) FOR A SHORT TO VOLTAGE
- Ignition OFF.
- Disconnect: HVAC Module - Electronic Manual Temperature Control (EMTC) C2357a.
- Disconnect: HVAC Module - Dual Automatic Temperature Control (DATC) C2356a.
- Ignition ON.
- Measure the voltage between HVAC module - DATC C2356A-2, circuit VH407 (YE/GN), harness side and ground.
- Is any voltage present?
- Yes: REPAIR circuit VH407 (YE/GN) for a short to ground. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- No: GO to E4.
- E4 CHECK CIRCUIT VH407 (YE/GN) FOR AN OPEN
- Ignition OFF.
- Measure the resistance between HVAC module - DATC C2356A-2, circuit VH407 (YE/GN), harness side and ambient air temperature sensor C132-1, circuit VH407 (YE/GN), harness side.
- Is the resistance less than 5 ohms?
- Yes: GO to E5.
- No: REPAIR circuit VH407 (YE/GN) for an open. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- E5 CHECK CIRCUIT RH111 (GY/BU) FOR AN OPEN
- Measure the resistance between HVAC module - DATC C2356A-10, circuit RH111 (GY/BU), harness side and ambient air temperature sensor C132-2, circuit RH111 (GY/BU), harness side.
- Is the resistance less than 5 ohms?
- Yes: GO to E8.
- No: REPAIR circuit RH111 (GY/BU) for an open. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- E6 CHECK CIRCUIT VH407 (YE/GN) FOR A SHORT TO CIRCUIT RH111 (GY/BU)
- Ignition OFF.
- Disconnect: HVAC Module - EMTC C2357a.
- Disconnect: HVAC Module - DATC C2356a.
- Measure the resistance between ambient air temperature sensor C132-1, circuit VH407 (YE/GN), harness side and C132-2, circuit RH111 (GY/BU), harness side.
- Is the resistance greater than 10, 000 ohms?
- Yes: GO to E7.
- No: REPAIR circuit VH407 (YE/GN) for a short to circuit RH111 (GY/BU). CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- E7 CHECK CIRCUIT VH407 (YE/GN) FOR A SHORT TO GROUND
- Measure the resistance between HVAC module - DATC C2356A-2, circuit VH407 (YE/GN), harness side and ground.
- Is the resistance greater than 10, 000 ohms?
- Yes: GO to E8.
- No: REPAIR circuit VH407 (YE/GN) for a short to ground. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- E8 CHECK THE MODULE CONNECTION
- Inspect the module connectors for:
- corrosion.
- pushed-out terminals.
- damaged terminals.
- Connect and correctly seat all the HVAC module connectors.
- Clear the DTCs.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes: INSTALL a new HVAC module. REFER to CLIMATE CONTROL . TEST the system for normal operation.
- No: The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
- Inspect the module connectors for: