A/C Compressor - External Leak Test
WARNING: This page is about a different variant/trim than selected.
- Install the appropriate adapter from the A/C Flush Adapter Kit on the port of the A/C compressor, using the existing manifold retaining bolt.
- Connect the high- and low-pressure lines of a manifold gauge set or a refrigerant recovery/recycling station to the corresponding fittings on the adapter.
- Attach the center hose of a manifold gauge set to a refrigerant container standing in an upright position.
- Open the low-pressure gauge valve, the high-pressure gauge valve and the valve on the refrigerant container to allow the refrigerant vapor to flow into the A/C compressor.
- Using the Refrigerant Leak Detector, check for leaks at the compressor shaft.
- If a shaft seal leak is found, install a new compressor shaft seal. If an external leak is found, install a new A/C compressor.
- When the leak test is complete, recover the refrigerant from the compressor.