Instrument Panel Cluster (IPC): Installation
- Position the IPC in the instrument panel and connect the electrical connector.
- Install the 3 screws.
- Install the IPC finish panel. Refer to INSTRUMENT PANEL AND CONSOLE .
- If a new IPC was installed, updated or reconfigured, carry out the parameter reset procedure. For additional information, refer to ANTI-THEFT - PASSIVE ANTI-THEFT SYSTEM (PATS) (non-hybrid) or ANTI-THEFT - PASSIVE ANTI-THEFT SYSTEM (PATS) - HYBRID (hybrid).
- If a new IPC was installed, program the integrated keys. For additional information, refer to ANTI-THEFT - PASSIVE ANTI-THEFT SYSTEM (PATS) (non-hybrid) or ANTI-THEFT - PASSIVE ANTI-THEFT SYSTEM (PATS) - HYBRID (hybrid).
- If a new IPC was installed, download the IPC configuration information from the scan tool into the new IPC. For additional information, refer to MODULE CONFIGURATION , PMI.
NOTE:
If a new IPC is installed, updated, or re-configured, the IPC and the PCM (non-hybrid) or Transmission Control Module (TCM) (hybrid) require a parameter reset to allow the IPC and the PCM or TCM to recognize each other. Failure to carry out the parameter reset to the IPC and the PCM or TCM can result in a no start condition.
NOTE:
The vehicles integrated keys (or standard Passive Anti-Theft System (PATS) keys) must be programmed to the new IPC.