Pinpoint Test E: The Roof Opening Panel Does Not Open Or Close
- E1 CHECK THE ROOF OPENING PANEL OPERATION
- Ignition ON.
- Attempt to operate the roof opening panel to the VENT position.
- Does the roof opening panel operate to the VENT position?
- Yes: GO to E2.
- No: GO to E3.
- E2 CHECK THE MOTOR/MODULE FOR INITIALIZATION
- Carry out the roof opening panel motor initialization procedure. Refer to Roof Opening Panel Motor Initialization .
- Is the concern still present?
- Yes: GO to E3.
- No: The system is operating normally at this time. The roof opening panel motor was not initialized.
- E3 CHECK THE POWER WINDOWS
- Ignition ON.
- Verify the power windows operate.
- Do the power windows operate?
- Yes: GO to E4.
- No: REFER to GLASS, FRAMES AND MECHANISMS to diagnose the accessory delay relay circuit.
- E4 CHECK THE ROOF OPENING PANEL SWITCH
- Ignition OFF.
- Disconnect: Roof Opening Panel Switch C912.
- Carry out the Roof Opening Panel Switch component test. Refer to COMPONENT TESTING for component testing.
- Is the roof opening panel switch OK?
- Yes: GO to E5.
- No: INSTALL a new roof opening panel switch. REFER to Roof Opening Panel Control Switch . TEST the system for normal operation.
- E5 CHECK VOLTAGE TO THE ROOF OPENING PANEL MOTOR/MODULE
- Ignition OFF.
- Disconnect: Roof Opening Panel Motor/Module C921.
- Ignition ON.
- Measure the voltage between roof opening panel motor/module C921-2, circuit CBP41 (BU) and C921-1, circuit SBB33 (RD), harness side and ground.
- Is the voltage greater than 10 volts?
- Yes: GO to E6.
- No:
VERIFY Smart Junction Box (SJB) fuse 41 (15A) and Battery Junction Box (BJB) fuse 33 (20A) are OK. If OK, REPAIR the circuit. TEST the system for normal operation.
If not OK, REFER to the Wiring Diagrams information to identify the possible causes of the circuit short. TEST the system for normal operation.
- E6 CHECK THE ROOF OPENING PANEL GROUND
- Ignition OFF.
- Measure the resistance between roof opening panel motor/module C921-4, circuit GD139 (BK/YE), harness side and ground.
- Is the resistance less than 5 ohms?
- Yes: GO to E7.
- No: REPAIR the circuit. TEST the system for normal operation.
- E7 CHECK SWITCH COMMON CIRCUIT FOR AN OPEN
- Measure the resistance between overhead console C912-4, circuit CPR39 (VT/WH) and roof opening panel motor/module C921-11, circuit CPR39 (VT/WH), harness side.
- Is the resistance less than 5 ohms?
- Yes: CHECK the overhead console jumper harness for loose pins, an open or a short in circuit CPR39 (VT/WH) between the roof opening panel switch socket and overhead console C912-4. If the overhead console jumper harness is not OK, INSTALL a new overhead console jumper harness and TEST the system for normal operation. If the overhead console jumper harness is OK, GO to E8.
- No: REPAIR the circuit. TEST the system for normal operation.
- E8 CHECK SWITCH CLOSE CIRCUIT FOR AN OPEN
- Measure the resistance between overhead console C912-7, circuit CPR40 (YE/OG) and roof opening panel motor/module C921-6, circuit CPR40 (YE/OG), harness side.
- Is the resistance less than 5 ohms?
- Yes: CHECK the overhead console jumper harness for loose pins, an open or a short in circuit CPR40 (YE/OG) between the roof opening panel switch socket and overhead console C912-7. If the overhead console jumper harness is not OK, INSTALL a new overhead console jumper harness and TEST the system for normal operation. If the overhead console jumper harness is OK, GO to E9.
- No: REPAIR the circuit. TEST the system for normal operation.
- E9 CHECK SWITCH OPEN CIRCUIT FOR AN OPEN
- Measure the resistance between overhead console C912-3, circuit CPR31 (VT/BN) and roof opening panel motor/module C921-5, circuit CPR31 (VT/BN), harness side.
- Is the resistance less than 5 ohms?
- Yes: CHECK the overhead console jumper harness for loose pins, an open or a short in circuit CPR31 (VT/BN) between the roof opening panel switch socket and overhead console C912-3. If the overhead console jumper harness is not OK, INSTALL a new overhead console jumper harness, and TEST the system for normal operation. If the overhead console jumper harness is OK, GO to E10.
- No: REPAIR the circuit. TEST the system for normal operation.
- E10 CHECK SWITCH AUTO CIRCUIT FOR AN OPEN
- Measure the resistance between overhead console C912-2, circuit CPR38 (WH/BU) and roof opening panel motor/module C921-7, circuit CPR38 (WH/BU), harness side.
- Is the resistance less than 5 ohms?
- Yes: CHECK the overhead console jumper harness for loose pins, an open or a short in circuit CPR38 (WH/BU) between the roof opening panel switch socket and overhead console C912-2. If the overhead console jumper harness is not OK, INSTALL a new overhead console jumper harness and TEST the system for normal operation. If the overhead console jumper harness is OK, GO to E11.
- No: REPAIR the circuit. TEST the system for normal operation.
- E11 CHECK THE ROOF OPENING PANEL MOTOR/MODULE FOR CORRECT OPERATION
- Disconnect the roof opening panel motor/module connector.
- Check for:
- corrosion.
- bent or pushed-out pins.
- Connect the roof opening panel motor/module connector and make sure it seats correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes: INSTALL a new roof opening panel motor/module. REFER to Roof Opening Panel Motor . TEST the system for normal operation.
- No: The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. TEST the system for normal operation.