Pinpoint Test D: A Single Power Window Is Inoperative - RH Front
NOTE:
Use the correct probe adapter(s) from the Flex Probe Kit when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- D1 CHECK THE RH FRONT WINDOW OPERATION FROM THE LH FRONT WINDOW CONTROL SWITCH
- Ignition ON.
- Operate the RH front window from the LH front window control switch.
- Does the RH front window operate from the LH front window control switch?
- Yes : GO to D8.
- No : GO to D2.
- D2 CHECK THE POWER TO THE WINDOW MOTOR
- Ignition OFF.
- Disconnect: RH Front Window Motor C608.
- Measure the voltage between RH front window motor C608-1, circuit SBP04 (GN/RD), harness side and ground.
- Is the voltage greater than 10 volts?
- Yes : GO to D3.
- No
: VERIFY Smart Junction Box (SJB) fuse 4 (30A) is OK. If OK, REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION in this service information. TEST the system for normal operation.
If not OK, REFER to the SYSTEM WIRING DIAGRAMS article, to identify the possible causes of the circuit short.
REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION in this service information. TEST the system for normal operation.
- D3 CHECK THE RH FRONT WINDOW MOTOR DELAYED ACCESSORY FEED
- Ignition ON.
- Measure the voltage between RH front window motor C608-3, circuit CBP41 (BU), harness side and ground.
- Is the voltage greater than 10 volts?
- Yes : GO to D4.
- No : REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION in this service information. TEST the system for normal operation.
- D4 CHECK THE RH FRONT WINDOW MOTOR GROUND
- Ignition OFF.
- Measure the resistance between RH front window motor C608-2, circuit GD145 (BK/BU), harness side and ground.
- Is the resistance less than 5 ohms?
- Yes : GO to D5.
- No : REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION in this service information. TEST the system for normal operation.
- D5 CHECK CIRCUIT CPW12 (GN/OG) FOR AN OPEN
- Disconnect: LH Front Window Control Switch C504.
- Measure the resistance between RH front window motor C608-5, circuit CPW12 (GN/OG), harness side and LH front window control switch C504-10, circuit CPW12 (GN/OG), harness side.
- Is the resistance less than 5 ohms?
- Yes : GO to D6.
- No : REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION in this service information. TEST the system for normal operation.
- D6 CHECK CIRCUIT CPW13 (BN/YE) FOR AN OPEN
- Measure the resistance between RH front window motor C608-4, circuit CPW13 (BN/YE), harness side and LH front window control switch C504-11, circuit CPW13 (BN/YE), harness side.
- Is the resistance less than 5 ohms?
- Yes : GO to D7.
- No : REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION in this service information. TEST the system for normal operation.
- D7 CHECK THE LH FRONT WINDOW CONTROL SWITCH
- Carry out the LH front window control switch component test. Refer to COMPONENT TESTING article, for component testing.
- Did the LH front window control switch pass the component test?
- Yes : INSTALL a new RH front window regulator motor. REFER to WINDOW REGULATOR MOTOR - FRONT DOOR in this service information. INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION in this service information. TEST the system for normal operation.
- No : INSTALL a new LH front window control switch. REFER to WINDOW CONTROL SWITCH in this service information. INITIALIZE the LH front window motor. REFER to WINDOW MOTOR INITIALIZATION in this service information. TEST the system for normal operation.
- D8 CHECK THE POWER TO THE RH FRONT WINDOW CONTROL SWITCH NOTE: Make sure the LH window control switch is in the UNLOCK position.
- Ignition OFF.
- Disconnect: RH Front Window Control Switch C604.
- Ignition ON.
- Measure the voltage between RH front window control switch C604-1, circuit CPW14 (VT/WH), harness side and ground.
- Is the voltage greater than 10 volts?
- Yes : GO to D9.
- No : REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION in this service information. TEST the system for normal operation.
- D9 CHECK CIRCUIT CPW12 (GN/OG) FOR AN OPEN
- Ignition OFF.
- Measure the resistance between RH front window motor C608-5, circuit CPW12 (GN/OG), harness side and RH front window control switch C604-3, circuit CPW12 (GN/OG), harness side.
- Is the resistance less than 5 ohms?
- Yes : GO to D10.
- No : REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION in this service information. TEST the system for normal operation.
- D10 CHECK CIRCUIT CPW13 (BN/YE) FOR AN OPEN
- Measure the resistance between RH front window motor C608-4, circuit CPW13 (BN/YE), harness side and RH front window control switch C604-2, circuit CPW13 (BN/YE), harness side.
- Is the resistance less than 5 ohms?
- Yes : GO to D11.
- No : REPAIR the circuit. DE-INITIALIZE, then INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION in this service information. TEST the system for normal operation.
- D11 CHECK THE RH FRONT WINDOW CONTROL SWITCH
- Carry out the RH front window control switch component test. Refer to COMPONENT TESTING article, for component testing.
- Did the window control switch pass the component test?
- Yes : INSTALL a new RH front window regulator motor. REFER to WINDOW REGULATOR MOTOR - FRONT DOOR in this service information. INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION in this service information. TEST the system for normal operation.
- No : INSTALL a new RH front window control switch. REFER to WINDOW CONTROL SWITCH in this service information. INITIALIZE the RH front window motor. REFER to WINDOW MOTOR INITIALIZATION in this service information. TEST the system for normal operation.