Pinpoint Test F: The Roof Opening Panel Does Not Have Soft Stop
WARNING: This page is about a different car, the 2008 Mercury Mariner and 2008 Ford Escape. However, it is still accessible from the selected car via links, so may be relevant.
- F1 CHECK THE ROOF OPENING PANEL POSITION SWITCH FOR A SHORT TO GROUND IN THE CLOSED POSITION
- Key in ON position.
- Close the roof opening panel.
- Key in OFF position.
- Disconnect: Roof Opening Panel Module Connector
- With the roof opening panel in the CLOSED position, measure the resistance between the roof opening panel module connector, pin 1, circuit (OG/WH), harness side and ground.
- Is the resistance greater than 10,000 ohms?
- F2 CHECK CIRCUIT (OG/WH) FOR A SHORT TO GROUND
- Disconnect: Roof Opening Panel Position Switch Connector
- Measure the resistance between the roof opening panel module connector, pin 1, circuit (OG/WH), harness side and ground.
- Is the resistance greater than 10,000 ohms?
- YES : INSTALL a new roof opening panel motor. REFER to Roof Opening Panel Motor . TEST the system for normal operation.
- NO : REPAIR the circuit. TEST the system for normal operation.
- F3 CHECK THE ROOF OPENING PANEL POSITION SWITCH FOR A SHORT TO GROUND IN THE COMFORT POSITION
- Key in OFF position.
- Connect: Roof Opening Panel Module Connector
- Key in ON position.
- Open the roof opening panel to the comfort position.
- Key in OFF position.
- Disconnect: Roof Opening Panel Module Connector
- With the roof opening panel in the comfort position, measure the resistance between the roof opening panel module connector, pin 1, circuit (OG/WH), harness side and ground.
- Is the resistance greater than 10,000 ohms?
- YES : Go to F4.
- NO : INSTALL a new roof opening panel motor. REFER to Roof Opening Panel Motor . TEST the system for normal operation.
- F4 CHECK THE ROOF OPENING PANEL POSITION SWITCH SIGNAL
- Disconnect: Roof Opening Panel Position Switch Connector
- Measure the voltage between the roof opening panel position switch connector, pin 2, circuit (OG/WH), harness side and ground.
- Is the voltage greater than 10 volts?
- F5 CHECK CIRCUIT (OG/WH) FOR AN OPEN
- Measure the resistance between the roof opening panel module connector, pin 1, circuit (OG/WH), harness side and the roof opening panel position switch connector, pin 2, circuit (OG/WH), harness side.
- Is the resistance less than 5 ohms?
- YES : INSTALL a new roof opening panel module. REFER to Roof Opening Panel Module . TEST the system for normal operation.
- NO : REPAIR the circuit. TEST the system for normal operation.
- F6 CHECK CIRCUIT (BK) FOR AN OPEN
- Measure the resistance between the roof opening panel position switch connector, pin 1, circuit (BK), harness side and ground.
- Is the resistance less than 5 ohms?
- YES : INSTALL a new roof opening panel motor. REFER to Roof Opening Panel Motor . TEST the system for normal operation.
- NO : REPAIR the circuit. TEST the system for normal operation.