Pinpoint Test L: The Courtesy Lamps Do Not Turn On With The Liftgate Open
WARNING: This page is about a different car, the 2007 Lincoln MKX and 2007 Ford Edge. However, it is still accessible from the selected car via links, so may be relevant.
CAUTION:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- L1 CHECK THE POWER LIFTGATE MODULE OR THE LIFTGATE LATCH
- Key in OFF position.
- Disconnect: Power Liftgate Module C4174b or Liftgate Latch C479
- Do the courtesy lamps illuminate?
- YES
: If equipped with a power liftgate, go to L4.
If equipped with a manual liftgate, INSTALL a new liftgate latch. REFER to HANDLES, LOCKS, LATCHES AND ENTRY SYSTEMS . TEST the system for normal operation.
- NO : Go to L2.
- L2 CHECK CIRCUIT CPL60 (BN/YE) FOR A SHORT TO GROUND
- Disconnect: SJB C2280c
- Measure the resistance between the SJB C2280c-16, circuit CPL60 (BN/YE), harness side and ground.
- Is the resistance greater than 10,000 ohms?
Courtesy of FORD MOTOR CO.
- YES : Go to L3.
- NO : REPAIR the circuit. CLEAR the DTCs. REPEAT the self-test.
- L3 CHECK FOR CORRECT SJB OPERATION
- Disconnect all the SJB connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- YES : INSTALL a new SJB. REFER to MULTIFUNCTION ELECTRONIC MODULES . TEST the system for normal operation.
- NO : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test.
- L4 CHECK FOR CORRECT POWER LIFTGATE MODULE OPERATION
- Disconnect all the power liftgate module connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the power liftgate module connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- YES : INSTALL a new power liftgate module. REFER to BODY CLOSURES . TEST the system for normal operation.
- NO : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test.