Normal Operation
If the power liftgate is operated from the power liftgate control switch (instrument panel), circuit CPR63 (GY/YE) is grounded by the open/close switch, which signals the liftgate/trunk module (LTM) of the open/close request.
If the power liftgate is in the closed position and the conditions are correct, the LTM supplies 12 volts to the unlatch/cinching motor on circuit CPR62 (WH/BU), 12 volts to the clutch on circuit CPR69 (BN/BU) and 12 volts to the motor on circuit CPR57 (GN/WH). As the liftgate is moving in the open direction, the LTM monitors the position sensor for door speed to detect obstacles.
If the power liftgate is in the open position and the conditions are correct, the LTM supplies 12 volts to the clutch on circuit CPR69 (BN/BU) and 12 volts to the motor on circuit CPR58 (GN/OG). As the liftgate is moving in the close direction, the LTM monitors the position sensor for door speed to detect obstacles.
| DTC Description | Fault Trigger Conditions |
|---|---|
|
When the FET driver was shorted to ground, array counter reaches 1/3 or 2/3 of maximum times, which is 240. |
|
When the FET driver was shorted to ground, array counter reaches the maximum counts, which is 240. |
|
The ratio of diagnostic feedback voltage (VFB) and switch battery voltage (VBS) is less than 0.088 for more than one second (for example, VFB/VBS less than 0.088). |
|
Feedback current does not change during powered releasing/cinching. |
|
The ratio of VFB and VBS is greater than 0.3 for more than one second (for example, VFB/VBS greater than 0.3). |
|
Feedback sensor power is less than 0.5 V for more than 3 seconds. |
|
Sensor signals are not in correct phase. |
|
Sensor signals are not in correct phase. |
|
Vbatt2 is less than 4 VDC when Vbatt1 (logic) greater than 8 VDC. |
|
Ratio of diagnostic feedback voltage/VBS is greater than 0.3 for more than one second. |
|
Switch signals are invalid at start of self-test or no signal transitions during releasing/cinching. |
|
Self-test exceeded the maximum test time as specified in the self-test sheet. |
|
Power liftgate motor feedback current does not change when pulse-width modulation (PWM) duty cycle reaches 60%. |
|
Ratio of diagnostic feedback voltage/VBS is less than 0.088 for more than one second. |
|
Diagnostic feedback indicates a short or open circuit for more than 120ms. |
This pinpoint test is intended to diagnose the following:
- Fuse(s)
- Power liftgate latch
- Motor/clutch assembly
- Optical sensor
- LTM
- Power liftgate rod
- Wiring, terminals or connectors