LEMON Manuals: Even more car manuals for everyone
Home >> Lincoln >> 2002 >> Navigator RWD >> Repair and Diagnosis >> General Information >> Computer Relearn Procedures >> General Motors (Cars) >> Theft Deterrent System Components >> 10-Minute Learn Procedure (Aurora, Bonneville, Deville, Eldorado, Intrigue, LeSabre, Park Avenue & Seville)

10-Minute Learn Procedure (Aurora, Bonneville, Deville, Eldorado, Intrigue, LeSabre, Park Avenue & Seville)

    NOTE: This procedure requires a Tech 2™ scan tool and a Techline™ terminal with current SPS (Service Programming System) software.
    NOTE: Use this procedure after replacing the Passkey® III (PK3) keys, theft deterrent control module or PCM.
    NOTE: If replacing a theft deterrent control module with a GM SPO Replacement Part, perform the procedure to setup a new theft deterrent control module prior to the 10-minute relearn procedure.
  1. Connect scan tool to vehicle.
  2. Turn ignition on, with engine off.
  3. Ensure that all power consuming devices are turned OFF on vehicle.
  4. With scan tool, select Request Info. under Service Programming System and follow scan tool on-screen instructions.
  5. Disconnect scan tool from vehicle and connect scan tool to a Techline™ terminal with the current Service Programming System (SPS) software.
  6. On the Techline terminal, select Service Programming System and follow Techline terminal on-screen instructions.
  7. Disconnect scan tool from Techline™ terminal and reconnect scan tool to vehicle.
  8. With a master Passkey® III key, turn ON the ignition, with engine OFF.
  9. With scan tool, select Program ECU under Service Programming System.
  10. At this point the scan tool must remain connected for the duration of the 10-minute relearn procedure.
  11. NOTE: On some vehicles, the SECURITY telltale maybe illuminated on steady for the duration of the 10-minute relearn procedure.
  12. Observe scan tool, after about 10 minutes, scan tool will display "Programming Successful, Turn OFF Ignition". The vehicle is now ready to relearn the key information and/or the passwords on the next ignition switch transition from OFF to ON.
  13. Turn OFF ignition and wait 5 seconds.
  14. With master Passkey® III key, start engine. The theft deterrent control module has now learned the key transponder information and PCM has now learned the fuel continue password.
  15. NOTE: Perform this step ONLY on vehicles with EXPORT configured theft deterrent control modules.
  16. Turn OFF the ignition and wait 15 seconds minimum.
  17. NOTE: Perform this step ONLY on vehicles with EXPORT configured theft deterrent control modules.
  18. With a second master Passkey® III key, start engine. The theft deterrent control module has now learned the second master Passkey® III key transponder information.
  19. Using scan tool, clear any DTCs.