Ignition Switch
Disconnect ignition switch harness connector. Check continuity between specified terminals with switch in appropriate position. See IGNITION SWITCH CONTINUITY TEST table. See Fig 1 . If continuity is not as specified, replace ignition switch.
IGNITION SWITCH CONTINUITY TEST
| Switch Position | Between Terminals No. | Continuity | |
|---|---|---|---|
| Run Power Circuit | |||
| Off | 1 & 6; 2 & 7 | No | |
| Accessory | 1 & 6; 2 & 7 | No | |
| Run | 1 & 6; 2 & 7 | Yes | |
| Start | 1 & 6; 2 & 7 | No | |
| Run/Start Power Circuit | |||
| Off | 5 & 7 | No | |
| Accessory | 5 & 7 | No | |
| Run | 5 & 7 | Yes | |
| Start | 5 & 7 | Yes | |
| Run/Acc Power Circuit | |||
| Off | 1 & 4 | No | |
| Accessory | 1 & 4 | Yes | |
| Run | 1 & 4 | Yes | |
| Start | 1 & 4 | No | |
| Start Power Circuit | |||
| Off | 1 & 3 | No | |
| Accessory | 1 & 3 | No | |
| Run | 1 & 3 | No | |
| Start | 1 & 3 | Yes | |
| Key Reminder Circuit | |||
| Key Out | 7 & 8 | No | |
| Key In | 7 & 8 | Yes | |