Ammeter, Fuel, Oil & Temperature Gauges
Removal and installation is identical for all four gauges and requires removal of cluster assembly from cluster housing. To remove a gauge, remove gauge retaining nuts at back of cluster. From front of cluster, remove trim cover, mask and lens assembly that covers gauge to be removed (four retaining screws). Withdraw gauge from cluster.