When the engine is started by stop and start control, the engine stop and start ECU controls the starter assembly by activating the ST NO. 1 relay via voltage from terminal STA.

If overcurrent is detected in the starter relay circuit, the engine stop and start ECU stores DTC P0615-11.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate Note
P0615-11 Starter Relay Circuit Short to Ground Both of the following conditions are met for 3 second (1 trip detection logic):
  • Ignition switch ON
  • Overcurrent to ST NO. 1 relay is detected.
  • Wire harness or connector
  • ST NO. 1 relay
  • Engine stop and start ECU
Comes on (For Mexico Models: Does not come on) Does not come on SAE Code: P0616