LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2025 >> NX 350h >> Repair and Diagnosis >> External Pages >> Different car >> Section 59 (Smart Access System (For Start) - Diagnostic Codes & Symptom Tests (1 Of 2)) >> SMART ACCESS SYSTEM WITH PUSH-BUTTON START (for Start Function, Gasoline Model) >> DTC B228B-00: Battery Circuit or Ground Circuit Energization Malfunction [11/2021 - ] >> Procedure

DTC B228B-00: Battery Circuit or Ground Circuit Energization Malfunction [11/2021 - ]: Procedure

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2025 Lexus NX 350, 2025 Lexus NX 250, 2024 Lexus NX 350, 2024 Lexus NX 250, and 2023 Lexus NX 350. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK HARNESS AND CONNECTOR (POWER SOURCE) 

    Pre-procedure1

    1. Disconnect the D58 certification ECU (smart key ECU assembly) connector.

      Procedure1

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      D58-6 (+B) - Body ground Always 11 to 14 V

      Result

      Proceed to
      OK
      NG

      Post-procedure1

    3. None

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR IN CIRCUIT CONNECTED TO POWER SOURCE 

    Result: 

    OK 

    See step  2

  2. CHECK HARNESS AND CONNECTOR (GROUND) 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      D58-29 (E) - Body ground Always Below 1 Ω

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    END (TEMPORARY CONNECTION FAILURE IS SUSPECTED). Refer to  HOW TO PROCEED WITH TROUBLESHOOTING [11/2021 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR IN CIRCUIT CONNECTED TO POWER SOURCE