Installation [11/2021 - ]: Procedure
- INSTALL NO. 6 FUEL TANK CUSHION
HINT:
Perform this procedure only when replacement of the No. 6 fuel tank cushion is necessary.
- INSTALL NO. 1 FUEL TANK PROTECTOR
- INSTALL NO. 2 FUEL TANK PROTECTOR
- INSTALL FUEL TANK VENT HOSE SUB-ASSEMBLY
- Engage the 2 clamps to install the fuel tank vent hose sub-assembly to the fuel tank sub-assembly.
- Connect the fuel tank evaporation tube sub-assembly to the fuel tank vent hose sub-assembly.
Refer to PRECAUTION [11/2021 - ]
- INSTALL FUEL TANK MAIN TUBE SUB-ASSEMBLY
- INSTALL FUEL TANK SUB-ASSEMBLY
-
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Set the fuel tank sub-assembly on an engine lifter.NOTE:
Using height adjustment attachments and plate lift attachments, keep the fuel tank sub-assembly horizontal.
- Using the engine lifter, slowly raise the fuel tank sub-assembly, and then temporarily install the No. 1 fuel tank band sub-assembly and No. 2 fuel tank band sub-assembly with the 4 bolts.NOTE:
- Be careful not to drop the fuel tank sub-assembly.
- When installing the fuel tank sub-assembly, tilt it slightly to prevent it from interfering with the surrounding parts.
- Tighten the 4 bolts in the order shown in the illustration.
Torque: 45 N.m (459 kgf/cm, 33 ft.lbf)
- Set the fuel tank sub-assembly on an engine lifter.
-
- CONNECT FUEL TANK FILLER PIPE ASSEMBLY
- Connect the fuel tank filler pipe assembly to the fuel tank sub-assembly.
Refer to PRECAUTION [11/2021 - ]
- Connect the fuel tank filler pipe assembly to the fuel tank sub-assembly.
- CONNECT FUEL TANK BREATHER TUBE
- Connect the fuel tank breather tube to the fuel tank breather tube sub-assembly.
Refer to PRECAUTION [11/2021 - ]
- Connect the fuel tank breather tube to the fuel tank breather tube sub-assembly.
- CONNECT FUEL TANK MAIN TUBE SUB-ASSEMBLY
- Connect the fuel tank main tube sub-assembly to the fuel pipe.
Refer to PRECAUTION [11/2021 - ]
- Engage the clamp.
- Connect the fuel tank main tube sub-assembly to the fuel pipe.
- CONNECT FUEL TANK VENT HOSE SUB-ASSEMBLY
- Connect the fuel tank vent hose sub-assembly to the fuel vapor containment valve (close tank with bolt valve assembly).
Refer to PRECAUTION [11/2021 - ]
- Connect the fuel tank vent hose sub-assembly to the fuel vapor containment valve (close tank with bolt valve assembly).
- ADD FUEL
- INSTALL FUEL SUCTION TUBE WITH PUMP AND GAUGE ASSEMBLY
Refer to INSTALLATION [11/2021 - ]
- INSTALL FRONT CENTER FLOOR COVER RH
- INSTALL FRONT FLOOR COVER LH
Bolt
Torque: 7.5 N.m (76 kgf/cm, 66 in.lbf)
- INSTALL ENGINE UNDER COVER HEAT INSULATOR
- INSTALL NO. 2 ENGINE UNDER COVER ASSEMBLY
Refer to PROCEDURE - Step 6