LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2025 >> NX 250 FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 40 (Hybrid Control System - Diagnostic Codes (1 Of 5)) >> Hybrid Control System >> DTC P0A1B-49: Drive Motor "A" Control Module Internal Electronic Failure [11/2021 - ] >> Monitor Description

Monitor Description

WARNING: This page is about a different car, the 2025 Lexus NX 350h, 2024 Lexus NX 350h, 2023 Lexus NX 350h, and 2022 Lexus NX 350h. However, it is still accessible from the selected car via links, so may be relevant.

The MG ECU (in the inverter with converter assembly) performs many diagnostic tests to verify proper operation of internal ECU systems. In one of these tests, the MG ECU checks for an R/D (Resolver/Digital converter) malfunction involving the motor resolver. If the MG ECU detects an R/D converter error, it will conclude that there is an internal malfunction involving the motor resolver and the hybrid vehicle control ECU will illuminate the MIL and store a DTC.