Removal [11/2021 - ]: Procedure
- REMOVE FRONT FENDER FRONT SPLASH SHIELD LH
Refer to PROCEDURE - Step 7 [11/2021 - 03/2024] , or refer to PROCEDURE - Step 7 [03/2024 - ]
- REMOVE FRONT FENDER FRONT SPLASH SHIELD RH
Refer to PROCEDURE - Step 8 [11/2021 - 03/2024] , or refer to PROCEDURE - Step 8 [03/2024 - ]
- REMOVE NO. 1 ENGINE UNDER COVER
Refer to PROCEDURE - Step 9 [11/2021 - 03/2024] , or refer to PROCEDURE - Step 9 [03/2024 - ]
- DRAIN ENGINE COOLANT (for Engine)
Refer to PROCEDURE - Step 4
- REMOVE INVERTER WITH CONVERTER ASSEMBLY
Refer to REMOVAL [11/2021 - ]
- REMOVE WIRING HARNESS CLAMP BRACKET
Refer to PROCEDURE - Step 10 [11/2021 - 03/2022] , or refer to PROCEDURE - Step 10 [03/2022 - ] - REMOVE FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY)
*a Retainer - - Pull out Pull off - Disconnect the outlet heater water hose B connector from the No. 2 water by-pass pipe sub-assembly.NOTE:
Remove any foreign matter on the No. 2 water by-pass pipe sub-assembly and outlet heater water hose B connector before performing this work.
1. Pull out the retainer to disengage the lock claws and pull off the outlet heater water hose B connector.
2. Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.
3. Cover the disconnected No. 2 water by-pass pipe sub-assembly and outlet heater water hose B connector with plastic bags to prevent damage and contamination.
- Disconnect the outlet heater water hose B connector from the No. 2 water by-pass pipe sub-assembly.
*a Retainer - - Pull out Pull off - Disconnect the inlet heater water hose B connector from the flow shutting valve (water by-pass hose assembly).NOTE:
Remove any foreign matter on the flow shutting valve (water by-pass hose assembly) and inlet heater water hose B connector before performing this work.
1. Pull out the retainer to disengage the lock claws and pull off the inlet heater water hose B connector.
2. Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.
3. Cover the disconnected inlet heater water hose B connector with a plastic bag to prevent damage and contamination.
- Disconnect the inlet heater water hose B connector from the flow shutting valve (water by-pass hose assembly).