  1. REMOVE FRONT FENDER FRONT SPLASH SHIELD LH 

    Refer to PROCEDURE - Step 7 [11/2021 - 03/2024] , or refer to PROCEDURE - Step 7 [03/2024 - ]

  2. REMOVE FRONT FENDER FRONT SPLASH SHIELD RH 

    Refer to PROCEDURE - Step 8 [11/2021 - 03/2024] , or refer to PROCEDURE - Step 8 [03/2024 - ]

  3. REMOVE NO. 1 ENGINE UNDER COVER 

    Refer to PROCEDURE - Step 9 [11/2021 - 03/2024] , or refer to PROCEDURE - Step 9 [03/2024 - ]

  4. DRAIN ENGINE COOLANT (for Engine) 

    Refer to PROCEDURE - Step 4

  5. REMOVE INVERTER WITH CONVERTER ASSEMBLY 

    Refer to REMOVAL [11/2021 - ]

  6. REMOVE WIRING HARNESS CLAMP BRACKET 
    Refer to PROCEDURE - Step 10 [11/2021 - 03/2022] , or refer to PROCEDURE - Step 10 [03/2022 - ]
  7. REMOVE FLOW SHUTTING VALVE (WATER BY-PASS HOSE ASSEMBLY) 
    1. GTY1077959Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. GTY1077815Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Retainer - -
      Pull out Pull off
      1. Disconnect the outlet heater water hose B connector from the No. 2 water by-pass pipe sub-assembly.
        NOTE:

        Remove any foreign matter on the No. 2 water by-pass pipe sub-assembly and outlet heater water hose B connector before performing this work.

        1. Pull out the retainer to disengage the lock claws and pull off the outlet heater water hose B connector.

        2. Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.

        3. Cover the disconnected No. 2 water by-pass pipe sub-assembly and outlet heater water hose B connector with plastic bags to prevent damage and contamination.

    3. GTY1078062Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      *a Retainer - -
      Pull out Pull off
      1. Disconnect the inlet heater water hose B connector from the flow shutting valve (water by-pass hose assembly).
        NOTE:

        Remove any foreign matter on the flow shutting valve (water by-pass hose assembly) and inlet heater water hose B connector before performing this work.

        1. Pull out the retainer to disengage the lock claws and pull off the inlet heater water hose B connector.

        2. Check that there is no foreign matter on the sealing surfaces of the disconnected water lines. Clean them if necessary.

        3. Cover the disconnected inlet heater water hose B connector with a plastic bag to prevent damage and contamination.

    4. GTY1077967Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002