Home >> Lexus >> 2025 >> NX 250 FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 22 (Heating / Air Conditioning System - Diagnostic Codes, Circuit Tests & Symptom Tests) >> AIR CONDITIONING SYSTEM (for HEV Model) >> DTC B141A-11: Room Temperature Sensor Circuit Short to Ground [11/2021 - ] >> Procedure

DTC B141A-11: Room Temperature Sensor Circuit Short to Ground [11/2021 - ]: Procedure

WARNING: This page is about a different car, the 2025 Lexus NX 350h, 2024 Lexus NX 350h, 2023 Lexus NX 350h, and 2022 Lexus NX 350h. However, it is still accessible from the selected car via links, so may be relevant.
  1. READ VALUE USING GTS (ROOM TEMPERATURE SENSOR) 
    1. Read the Data List according to the display on the GTS.

      Body Electrical > Air Conditioner > Data List 

      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Room Temperature Sensor Room temp. sensor (cooler thermistor) -327.68 to 327.67°C Actual cabin temperature displayed Room temp. sensor (cooler thermistor) circuit malfunction

      Body Electrical > Air Conditioner > Data List 

      Tester Display
      Room Temperature Sensor

      OK

      The display is as specified in the normal condition column.

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [11/2021 - ] 

    Result: 

    NG 

    See step  2

  2. INSPECT ROOM TEMP. SENSOR (COOLER THERMISTOR) 

    Refer to INSPECTION [11/2021 - ]

    Result

    Proceed to
    OK
    NG

    Result: 

    NG 

    REPLACE ROOM TEMP. SENSOR (COOLER THERMISTOR). Refer to  REMOVAL [11/2021 - ] 

    Result: 

    OK 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - ROOM TEMP. SENSOR (COOLER THERMISTOR)) 
    1. Disconnect the D65 room temp. sensor (cooler thermistor) connector.
    2. Disconnect the D53 air conditioning amplifier assembly connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      D65-1 or D53-5 (TR) - Other terminals and body ground Always 10 kΩ or higher
      D65-2 or D53-3 (SG-1) - Other terminals and body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [11/2021 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR