Home >> Lexus >> 2024 >> TX 350 Base, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 94 (Hybrid Transaxle System (Pc60) - Diagnostic Codes (4 Of 4) & Circuit Tests) >> Hybrid Transaxle System >> DTC P27CD-13: Pressure Control Solenoid "R" Control Circuit Open [09/2023 - ] >> Typical Enabling Conditions

Typical Enabling Conditions

WARNING: This page is about a different car, the 2024 Lexus TX 500h. However, it is still accessible from the selected car via links, so may be relevant.
DS_active_wake*1 TRUE
Pressure control solenoid driver error (P1700) Not detected
Solenoid current cut status Not cut
Time after solenoid current cut status cut to not cut 0.02 seconds or more
Detection condition by HSDN*2 TRUE
Pressure control solenoid driver status BATT short Not Occurred
Pressure control solenoid driver status GND short Not Occurred
Solenoid (SL8) valve error (P27CF, P27D0) Not detected
Target current 0.02 A or higher

HINT: 

*1: DS_active_wake

Following condition is met 0.5 seconds or more
Auxiliary battery voltage 9.5 V or higher

*2: Detection condition by HSDN

Either of the following conditions is met (A) or (B)
(A) All of the following conditions are met -
Lost communication with hybrid/EV powertrain control module (ch5) fault Not detected
Lost communication with hybrid/EV powertrain control module (ch5) malfunction (U11B3) Not detected
Powertrain local bus back up running not required -
HSDNTM signal from Hybrid/EV OFF
Time after HSDNTM signal from hybrid/EV ON to OFF 0.06 seconds or more
Either of the following conditions is met (a) or (b)
(a) Both conditions are met -
- Solenoid current cut status from HSDNM Cut
- Time after solenoid current cut status from HSDNM not cut to cut 0.06 seconds or more
(b) Both conditions are met -
- Solenoid current cut status from HSDNM Not cut
- Time after solenoid current cut status from HSDNM cut to not cut 0.02 seconds or more
(B) All of the following conditions are met -
One of the following conditions is met (a), (b) or (c)
(a) Lost communication with hybrid/EV powertrain control module (ch5) fault Detected
(b) Lost communication with hybrid/EV powertrain control module (ch5) malfunction (U11B3) Detected
(c) Powertrain local bus back up running required -
Solenoid current cut status from HSDNM Not cut
Time after solenoid current cut status from HSDNM cut to not cut 0.02 seconds or more