Inspection [09/2023 - ]: Procedure
- INSPECT SOLENOID (SL1) VALVE
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result 1 - 2 20 °C (68 °F) 5.0 to 5.6 Ω Ω *a Component without harness connected
(Solenoid (SL1) Valve) - Connect a positive (+) lead from the auxiliary battery with a 21 W bulb to terminal 1 and a negative (-) lead to terminal 2 of the solenoid (SL1) valve connector, and check that the solenoid (SL1) valve moves and makes an operating sound.NOTE:
When using auxiliary battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
OK
The solenoid (SL1) valve moves and makes an operating sound.
If the result is not as specified, replace the solenoid (SL1) valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SOLENOID (SL2) VALVE
HINT:
Use the same procedure as for the solenoid (SL1) valve.
- INSPECT SOLENOID (SL3) VALVE
HINT:
Use the same procedure as for the solenoid (SL1) valve.
- INSPECT SOLENOID (SL5) VALVE
HINT:
Use the same procedure as for the solenoid (SL1) valve.
- INSPECT SOLENOID (SL6) VALVE
HINT:
Use the same procedure as for the solenoid (SL1) valve.
- INSPECT SOLENOID (SL7) VALVE
HINT:
Use the same procedure as for the solenoid (SL1) valve.
- INSPECT SOLENOID (SL8) VALVE
HINT:
Use the same procedure as for the solenoid (SL1) valve.
- INSPECT SOLENOID (SLT) VALVE
HINT:
Use the same procedure as for the solenoid (SL1) valve.
- INSPECT SOLENOID (SR) VALVE
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result Solenoid (SR) valve connector terminal - Solenoid (SR) valve body 20 °C (68 °F) 11 to 15 Ω Ω *a Component without harness connected
(Solenoid (SR) Valve) - Connect a positive (+) lead from the auxiliary battery to the terminal of the solenoid (SR) valve connector and a negative (-) lead to the solenoid (SR) valve body, and check that the solenoid (SR) valve moves and makes an operating sound.NOTE:
When using auxiliary battery voltage during the inspection, do not bring the positive (+) and negative (-) tester probes too close to each other as a short circuit may occur.
OK
The solenoid (SR) valve moves and makes an operating sound.
If the result is not as specified, replace the solenoid (SR) valve.
- Measure the resistance according to the value(s) in the table below.
- INSPECT SOLENOID (SRL1) VALVE
HINT:
Use the same procedure as for the solenoid (SR) valve.
- INSPECT SOLENOID (SC2) VALVE
HINT:
Use the same procedure as for the solenoid (SR) valve.
- INSPECT SOLENOID (SC4) VALVE
HINT:
Use the same procedure as for the solenoid (SR) valve.
- INSPECT SOLENOID (SC6) VALVE
HINT:
Use the same procedure as for the solenoid (SR) valve.