On-Vehicle Inspection [12/2023 - ]: Procedure
WARNING: This page is about a different car, the 2024 Lexus TX 550h+. However, it is still accessible from the selected car via links, so may be relevant.
- CHECK AUXILIARY BATTERY
- Check that the auxiliary battery cables are connected to the correct terminals.
If they are not, connect them properly.
- Check the auxiliary battery for damage and deformation. If severe damage, deformation or leakage is found, replace the auxiliary battery.
- Check the electrolyte level in each cell.
- For maintenance-free batteries:
- If the electrolyte level is below the lower line, replace the battery.
- For non-maintenance-free batteries:
- If the electrolyte level is below the lower line, add distilled water to each cell. Then, recharge the auxiliary battery and check the electrolyte specific gravity.
Standard Specific Gravity
1.25 or higher at 20°C (68°F)
- If the electrolyte level is below the lower line, add distilled water to each cell. Then, recharge the auxiliary battery and check the electrolyte specific gravity.
- For maintenance-free batteries:
- Check that the auxiliary battery cables are connected to the correct terminals.
- CHECK AUXILIARY BATTERY VOLTAGE
- Turn the ignition switch off and turn on the headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.
- Measure the auxiliary battery voltage according to the value(s) in the table below.
Result
Tester Connection Condition Specified Condition Result Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 20°C (68°F), Ignition switch off 12.0 V or higher Auxiliary battery is OK 12.0 V or less Recharge auxiliary battery
- RECHARGE AUXILIARY BATTERY
- Recharge the auxiliary battery.
HINT:
- Recharge the auxiliary battery according to the charger's instructions.
- Apply the appropriate charging current according to the type of auxiliary battery shown in the table below.
Charge Method Charging Current Normal Below 5 A - Turn the ignition switch off and turn on the headlights for 30 seconds. This will remove the surface charge from the auxiliary battery.
- Turn the headlights off.
- Measure the auxiliary battery voltage according to the value(s) in the table below.
Result
Tester Connection Condition Specified Condition Result Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 20°C (68°F), Ignition switch off 12.0 V or higher Auxiliary battery is OK 12.0 V or less Recharge auxiliary battery
- Recharge the auxiliary battery.
- CHECK AUXILIARY BATTERY TERMINAL, FUSIBLE LINK AND FUSE
- Check that the auxiliary battery terminals are not loosen or corroded.
If a terminal is loose or corroded, tighten or clean the terminal.
Standard
Battery Terminal Specified Condition Positive (+) terminal 5.0 N*m
51 kgf*cm
44 in.*lbfNegative (-) terminal 5.4 N*m
55 kgf*cm
48 in.*lbf - Check whether the battery state sensor assembly is deformed or cracked.
- Measure the resistance of each fusible link and fuse for the auxiliary battery charging system.
Standard Resistance
Below 1 Ω
If the result is not as specified, replace the fusible link or fuse as necessary.
- Check that the auxiliary battery terminals are not loosen or corroded.
- CHECK DC/DC CONVERTER FUNCTION
- Connect the AC/DC 400 A probe to the positive (+) auxiliary battery cable.
*a Probe Direction *b Current Flowing into Auxiliary Battery - Turn the ignition switch on (READY) and leave the vehicle as is until the electric current flowing to the auxiliary battery becomes 10 A or less.
- Turn on the high beam headlights, and turn the blower motor switch to the HI position and the rear window defogger on.
- Measure the current and voltage according to the value(s) in the table below.
*a Probe Direction *b Current Flowing from Auxiliary Battery Result
Item Tester Connection Condition Specified Condition Current flowing from auxiliary battery Positive (+) auxiliary battery cable Ignition switch on (READY)
(The high beam headlights are on, the blower motor switch is in the HI position, and the rear window defogger is turned on.)0 A or less
(No current from auxiliary battery)Auxiliary battery voltage Positive (+) auxiliary battery terminal - Negative (-) auxiliary battery terminal 12.5 to 15 V If the result is not as specified, replace the DC/DC converter.
- Connect the AC/DC 400 A probe to the positive (+) auxiliary battery cable.