Inspection [12/2023 - ]: Procedure
- INSPECT NO. 2 TRACTION BATTERY DEVICE BOX ASSEMBLY
- Inspect SMRB:
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(No. 2 Traction Battery Device Box Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition 1 (+) - 1 (CBI) Auxiliary battery voltage not applied between terminals 3(SMRB) and 2(GND) 10 kΩ or higher Auxiliary battery voltage applied between terminals 3(SMRB) and 2(GND) Below 1 Ω 1(+) - 2(CBI2) Auxiliary battery voltage not applied between terminals 3(SMRB) and 2(GND) 10 kΩ or higher Auxiliary battery voltage applied between terminals 3(SMRB) and 2(GND) Below 1 Ω - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3 (SMRB) - 2 (GND) -40 to 80°C (-40 to 176°F) 18.2 to 36.0 Ω If the result is not as specified, replace the No. 2 traction battery device box assembly.
- Measure the resistance according to the value(s) in the table below.
- Inspect SMRG:
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(No. 2 Traction Battery Device Box Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition 1(-) - 2(CEI) Auxiliary battery voltage not applied between terminals 1(SMRG) and 5(GND8) 10 kΩ or higher Auxiliary battery voltage applied between terminals 1(SMRG) and 5(GND8) Below 1 Ω 1(-) - 1(CEI2) Auxiliary battery voltage not applied between terminals 1(SMRG) and 5(GND8) 10 kΩ or higher Auxiliary battery voltage applied between terminals 1(SMRG) and 5(GND8) Below 1 Ω - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1(SMRG) - 5(GND8) -40 to 80°C (-40 to 176°F) 18.2 to 36.0 Ω If the result is not as specified, replace the No. 2 traction battery device box assembly.
- Measure the resistance according to the value(s) in the table below.
- Inspect SMRP:
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(No. 2 Traction Battery Device Box Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition 1 (-) - 2 (CEI) Auxiliary battery voltage not applied between terminals 4 (SMRP) and 5 (GND8) 10 kΩ or higher Auxiliary battery voltage applied between terminals 4 (SMRP) and 5 (GND8) 28.5 to 31.5 Ω 1(-) - 1(CEI2) Auxiliary battery voltage not applied between terminals 4 (SMRP) and 5 (GND8) 10 kΩ or higher Auxiliary battery voltage applied between terminals 4 (SMRP) and 5 (GND8) Below 1 Ω - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 4 (SMRP) - 5 (GND8) -40 to 80°C (-40 to 176°F) 140 to 290 Ω If the result is not as specified, replace the No. 2 traction battery device box assembly.
- Measure the resistance according to the value(s) in the table below.
- Inspect CHRB:
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(No. 2 Traction Battery Device Box Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition 1(+) - 1(DCHB) Auxiliary battery voltage not applied between terminals 1(CHRB) and 2(GND) 10 kΩ or higher Auxiliary battery voltage applied between terminals 1(CHRB) and 2(GND) Below 1 Ω - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 1(CHRB) - 2(GND) -40 to 80°C (-40 to 176°F) 20.6 to 40.8 Ω If the result is not as specified, replace the No. 2 traction battery device box assembly.
- Measure the resistance according to the value(s) in the table below.
- Inspect CHRG:
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(No. 2 Traction Battery Device Box Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition 1(-) - 1(DCHG) Auxiliary battery voltage not applied between terminals 3(CHRG) and 5(GND8) 10 kΩ or higher Auxiliary battery voltage applied between terminals 3(CHRG) and 5(GND8) Below 1 Ω - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 3(CHRG) - 5(GND8) -40 to 80°C (-40 to 176°F) 20.6 to 40.8 Ω If the result is not as specified, replace the No. 2 traction battery device box assembly.
- Measure the resistance according to the value(s) in the table below.
- Inspect CHRP:
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(No. 2 Traction Battery Device Box Assembly)- - Standard Resistance
Tester Connection Condition Specified Condition 1(-) - 1(DCHG) Auxiliary battery voltage not applied between terminals 2(CHRP) and 5(GND8) 10 kΩ or higher Auxiliary battery voltage applied between terminals 2(CHRP) and 5(GND8) Below 1 Ω - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition 2(CHRP) - 5(GND8) -40 to 80°C (-40 to 176°F) 28.5 to 31.5 Ω If the result is not as specified, replace the No. 2 traction battery device box assembly.
- Measure the resistance according to the value(s) in the table below.
- Inspect SMRB: