LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2024 >> TX 350 Base, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 117 (Heating / Air Conditioning System - Diagnostic Codes (3 Of 3) & Symptom Tests) >> AIR CONDITIONING SYSTEM (for PHEV Model) >> DTC P15B9-62: Ambient Temperature Sensor / Ambient Temperature Sensor "B" Signal Compare Failure [12/2023 - ] >> Procedure

DTC P15B9-62: Ambient Temperature Sensor / Ambient Temperature Sensor "B" Signal Compare Failure [12/2023 - ]: Procedure

WARNING: This page is about a different car, the 2024 Lexus TX 550h+. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK DTC (AIR CONDITIONING SYSTEM) 
    1. Check if air conditioning system DTCs are output.

      Body Electrical > Air Conditioner > Trouble Codes 

      HINT: 

      Check even when the DTCs detected for temporary failures.

      Result

      Result Proceed to
      No DTCs in the table below are output A
      Any of the DTCs in the table below are output B
      Relevant DTC
      P0070-11 Ambient Temperature Sensor Circuit Short to Ground
      P0070-15 Ambient Temperature Sensor Circuit Short to Battery or Open
      P00D9-11 Ambient Temperature Sensor "B" Circuit Short to Ground
      P00D9-15 Ambient Temperature Sensor "B" Circuit Short to Battery or Open

    Result: 

    GO TO DIAGNOSTIC TROUBLE CODE CHART (AIR CONDITIONING SYSTEM). Refer to  DIAGNOSTIC TROUBLE CODE CHART [12/2023 - ] 

    Result: 

    See step  2

  2. READ VALUE USING GTS 

    Pre-procedure1

    • Place the thermometer in a well-ventilated location in the shade.
    • Move the vehicle to a well-ventilated location in the shade.
    • Blower switch turned off.
    • Wait for 1 hour after turning the ignition switch off.
    • Read the Data List according to the display on the GTS.

      Body Electrical > Air Conditioner > Data List 

      Tester Display Measurement Item Range Normal Condition Diagnostic Note
      Ambient Temperature Sensor Ambient temp. sensor (thermistor assembly) -327.68 to 327.67°C Actual ambient temperature displayed Ambient temp. sensor (thermistor assembly) circuit malfunction
      Ambient Temperature Sensor "B" No. 2 ambient temp. sensor (thermistor assembly) -327.68 to 327.67°C Actual ambient temperature displayed No. 2 ambient temp. sensor (thermistor assembly) circuit malfunction

      Body Electrical > Air Conditioner > Data List 

      Tester Display
      Ambient Temperature Sensor
      Ambient Temperature Sensor "B"
    • Compare the values displayed in the Data List and on the manifold gauge set.

      Result

      Result Proceed to
      The Data List value for the cooler ambient temp. sensor (thermistor assembly) does not match the value of the thermometer A
      The Data List value for the No. 2 ambient temp. sensor (thermistor assembly) does not match the value of the thermometer B
      Data List values and thermometer values match C

    Post-procedure1

    • None

    Result: 

    See step  5

    Result: 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [09/2023 - ] 

    Result: 

    See step  3

  3. INSPECT AMBIENT TEMP. SENSOR (THERMISTOR ASSEMBLY) 

    Refer to INSPECTION [09/2023 - ]

    Result

    Proceed to
    OK
    NG

    Result: 

    NG 

    REPLACE AMBIENT TEMP. SENSOR (THERMISTOR ASSEMBLY). Refer to  REMOVAL [12/2023 - ] 

    Result: 

    OK 

    See step  4

  4. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AMBIENT TEMP. SENSOR (THERMISTOR ASSEMBLY)) 

    Pre-procedure1

    • Disconnect the D35 air conditioning amplifier assembly connector.
    • Disconnect the B13 ambient temp. sensor (thermistor assembly) connector.
    • Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition Result
      D35-1 (TAM) - B13-1 (+) Always Below 1 Ω Ω
      D35-14 (SG-2) - B13-2 (-) Always Below 1 Ω Ω
      D35-1 (TAM) or B13-1 (+) - Other terminals and body ground Always 10 kΩ or higher
      D35-14 (SG-2) or B13-2 (-) - Other terminals and body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Post-procedure1

    • None

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [09/2023 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

  5. INSPECT NO. 2 AMBIENT TEMP. SENSOR (THERMISTOR ASSEMBLY) 

    Refer to INSPECTION [09/2023 - ]

    Result

    Proceed to
    OK
    NG

    Result: 

    NG 

    REPLACE NO. 2 AMBIENT TEMP. SENSOR (THERMISTOR ASSEMBLY). Refer to  REMOVAL [12/2023 - ] 

    Result: 

    OK 

    See step  6

  6. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - NO. 2 AMBIENT TEMP. SENSOR (THERMISTOR ASSEMBLY)) 

    Pre-procedure1

    • Disconnect the D35 and D37 air conditioning amplifier assembly connector.
    • Disconnect the B87 No. 2 ambient temp. sensor (thermistor assembly) connector.
    • Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition Result
      D37-10 (TAMB) - B87-1 (+) Always Below 1 Ω Ω
      D35-14 (SG-2) - B87-2 (-) Always Below 1 Ω Ω
      D37-10 (TAMB) or B87-1 (+) - Other terminals and body ground Always 10 kΩ or higher
      D35-14 (SG-2) or B87-2 (-) - Other terminals and body ground Always 10 kΩ or higher

      Result

      Proceed to
      OK
      NG

    Post-procedure1

    • None

    Result: 

    OK 

    REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to  REMOVAL [09/2023 - ] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR