DTC P1501-7A: Hybrid/EV Battery Cooling Refrigerant Gas Fluid Leak or Seal Failure [12/2023 - ]: Procedure
- CHECK DTC (AIR CONDITIONING SYSTEM)
- Check for DTCs.
Body Electrical > Air Conditioner > Trouble Codes
HINT:
Check even when the DTCs detected for temporary failures.
Result
Result Proceed to Only P1501-7A is output A P1501-7A and P0070-11 are output B P1501-7A and P0070-15 are output C P1501-7A and P0530-11 are output D P1501-7A and P0530-15 are output E P1501-7A and P0530-1C are output F P1501-7A and P15B9-62 are output G Relevant DTC P0070-11 Ambient Temperature Sensor Circuit Short to Ground P0070-15 Ambient Temperature Sensor Circuit Short to Battery or Open P0530-11 Refrigerant Pressure Sensor Circuit Short to Ground P0530-15 Refrigerant Pressure Sensor Circuit Short to Battery or Open P0530-1C Refrigerant Pressure Sensor Circuit Voltage Out of Range P15B9-62 Ambient Temperature Sensor / Ambient Temperature Sensor "B" Signal Compare Failure
Result:
B
GO TO DTC CHART (P0070-11). Refer to DTC P0070-11: Ambient Temperature Sensor Circuit Short to Ground [12/2023 - ]
Result:
C
GO TO DTC CHART (P0070-15). Refer to DTC P0070-15: Ambient Temperature Sensor Circuit Short to Battery or Open [12/2023 - ]
Result:
D
GO TO DTC CHART (P0530-11). Refer to DTC P0530-11: Refrigerant Pressure Sensor Circuit Short to Ground [12/2023 - ]
Result:
E
GO TO DTC CHART (P0530-15). Refer to DTC P0530-15: Refrigerant Pressure Sensor Circuit Short to Battery or Open [12/2023 - ]
Result:
F
GO TO DTC CHART (P0530-1C). Refer to DTC P0530-1C: Refrigerant Pressure Sensor Circuit Voltage Out of Range [12/2023 - ]
Result:
G
GO TO DTC CHART (P15B9-62). Refer to DTC P15B9-62: Ambient Temperature Sensor / Ambient Temperature Sensor "B" Signal Compare Failure [12/2023 - ]
Result:
A
See step 2
- Check for DTCs.
- COMPARE REFRIGERANT GAS PRESSURE VALUES SHOWN ON GTS AND MANIFOLD GAUGE SET
HINT:
This check is meant to compare the refrigerant gas pressure with GTS data when the engine is stopped and observed and the air conditioning tool, so do not operate the compressor.
Pre-procedure1
- Blower switch turn off.
- Wait for 60 minutes after turning the ignition switch off.
- Install a manifold gauge set.
- Read the Data List according to the display on the GTS.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Regulator Pressure Sensor Air conditioning pressure sensor -32768 to 32767 kPa(gauge) (-32.768 to 32.767 MPaG) Actual refrigerant pressure displayed - Refrigerant line(gas leak etc.)
- Air conditioning pressure sensor circuit malfunction
Body Electrical > Air Conditioner > Data List
Tester Display Regulator Pressure Sensor - Compare the values displayed in the Data List and on the manifold gauge set.
Result
Result Proceed to Data List values and air conditioning tool set values match A Data List values and air conditioning tool set values does not match B
Post-procedure1
- None
Result:
A
INSPECT REFRIGERANT PRESSURE WITH MANIFOLD GAUGE SET. Refer to ON-VEHICLE INSPECTION [09/2023 - ]
Result:
B
See step 3
- CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
Pre-procedure1
- Disconnect the B16 air conditioning pressure sensor connector.
- Measure the voltage according to the value(s) in the table below.
*a Front view of wire harness connector
(to Air Conditioning Pressure Sensor)Standard Voltage
Tester Connection Condition Specified Condition Result B16-3 (+) - Body ground Ignition switch ON 4.75 to 5.25 V V Result
Proceed to OK NG
Post-procedure1
- None
Result:
NG
See step 9
Result:
OK
See step 4
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - BODY GROUND)
Pre-procedure1
- Disconnect the B16 air conditioning pressure sensor connector.
- Measure the resistance according to the value(s) in the table below.
*a Front view of wire harness connector
(to Air Conditioning Pressure Sensor)Standard Resistance
Tester Connection Condition Specified Condition Result B16-1 (-) - Body ground Always Below 1 Ω Ω Result
Proceed to OK NG
Post-procedure1
- None
Result:
NG
See step 8
Result:
OK
See step 5
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)
Pre-procedure1
- Disconnect the D35 air conditioning amplifier assembly connector.
- Disconnect the B16 air conditioning pressure sensor connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result D35-6 (PRE) - B16-2 (PR) Always Below 1 Ω Ω D35-6 (PRE) or B16-2 (PR) - Other terminals and body ground Always 10 kΩ or higher kΩ Result
Proceed to OK NG
Post-procedure1
- None
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 6
- INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT) NOTE:
- If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), a fail-safe function will stop compressor operation. In this case, make sure to measure the voltage before the fail-safe function operates.
- It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
Pre-procedure1
- Connect the D35 air conditioning amplifier assembly connector.
- Measure the voltage with the following conditions met.
Measurement Condition
Item Condition Vehicle doors Fully open Temperature setting MAX COLD Blower speed HI A/C switch On Recirculation/fresh switch Recirculation Interior temperature 25 to 35°C (77 to 95°F)
- Measure the voltage according to the value(s) in the table below.
*a Component with harness connected
(Air Conditioning Amplifier Assembly)- - Standard Voltage
Tester Connection Condition Specified Condition Result D35-6 (PRE) - Body ground A/C switch on
(Compressor operating)0.62 to 4.73 V V HINT:
When the ambient air temperature is low (below -1.5°C (29.3°F)), the compressor will be stopped, due to inputs of the thermistor assembly and No. 1 cooler thermistor, to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
OK
The voltage value changes.
Result
Proceed to OK NG
Post-procedure1
- None
Result:
NG
REPLACE AIR CONDITIONING PRESSURE SENSOR. Refer to REMOVAL [12/2023 - ]
Result:
OK
See step 7
- INSPECT AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT) NOTE:
- If refrigerant pressure on the high pressure side becomes extremely high during the inspection (if the voltage exceeds 4.61 V), a fail-safe function will stop compressor operation. In this case, make sure to measure the voltage before the fail-safe function operates.
- It is necessary to measure the voltage for a certain amount of time (approximately 10 minutes) because the malfunction may recur after a while.
Pre-procedure1
- Measure the voltage with the following conditions met.
Measurement Condition
Item Condition Vehicle doors Fully open Temperature setting MAX COLD Blower speed HI A/C switch On Recirculation/fresh switch Recirculation Interior temperature 25 to 35°C (77 to 95°F)
- Read the Data List according to the display on the GTS.
Body Electrical > Air Conditioner > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Regulator Pressure Sensor Air conditioning pressure sensor -32768 to 32767 kPa(gauge) (-32.768 to 32.767 MPaG) Actual refrigerant pressure displayed - Refrigerant line (gas leak etc.)
- Air conditioning pressure sensor circuit malfunction
Body Electrical > Air Conditioner > Data List
Tester Display Regulator Pressure Sensor HINT:
When the ambient air temperature is low (below -1.5°C (29.3°F)), the compressor will be stopped, due to inputs of the thermistor assembly and No. 1 cooler thermistor, to prevent the evaporator from freezing. In this case, perform the inspection in a warm indoor environment.
OK
The value displayed in the Data List changes.
Result
Proceed to OK NG
Post-procedure1
- None
Result:
OK
USE SIMULATION METHOD TO CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [09/2023 - ]
Result:
NG
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [09/2023 - ]
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Pre-procedure1
- Disconnect the B16 air conditioning pressure sensor connector.
- Disconnect the D35 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result B16-1 (-) - D35-15 (SG-4) Always Below 1 Ω Ω B16-1 (-) or D35-15 (SG-4) - Other terminals and body ground Always 10 kΩ or higher kΩ Result
Proceed to OK NG
Post-procedure1
- None
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [09/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - AIR CONDITIONING AMPLIFIER ASSEMBLY)
Pre-procedure1
- Disconnect the B16 air conditioning pressure sensor connector.
- Disconnect the D35 air conditioning amplifier assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition Result B16-3 (+) - D35-11 (S5-3) Always Below 1 Ω Ω B16-3 (+) or D35-11 (S5-3) - Other terminals and body ground Always 10 kΩ or higher kΩ Result
Proceed to OK NG
Post-procedure1
- None
Result:
OK
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY. Refer to REMOVAL [09/2023 - ]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR