Home >> Lexus >> 2024 >> TX 350 Base, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 116 (Heating / Air Conditioning System - Diagnostic Codes (2 Of 3)) >> AIR CONDITIONING SYSTEM (for PHEV Model) >> DTC P0CDF-72: Hybrid/EV Battery Cooling Magnetic Valve Actuator Stuck Open [12/2023 - ] >> Typical Enabling Conditions

Typical Enabling Conditions

WARNING: This page is about a different car, the 2024 Lexus TX 550h+. However, it is still accessible from the selected car via links, so may be relevant.
Monitor runs whenever the following DTCs are not stored B3A0A (A/C Refrigerant Expansion Valve Actuator Stuck/Open)
B1385 (A/C Refrigerant Expansion Valve Actuator "B" Stuck/Open)
P0EC9 (A/C Refrigerant Distribution Valve "A" Stuck/Open)
P15B9 (Ambient Temperature Sensor / Ambient Temperature Sensor "B" Signal Compare Failure)
P0072 (Ambient Air Temperature Sensor Circuit "A" Low)
P0073 (Ambient Air Temperature Sensor Circuit "A" High)
P00DB (Ambient Air Temperature Sensor Circuit "B" Low)
P00DC (Ambient Air Temperature Sensor Circuit "B" High)
P2612 (A/C Refrigerant Distribution Valve "A" Control Circuit Low)
P2613 (A/C Refrigerant Distribution Valve "A" Control Circuit High)
B3A0C (A/C Refrigerant Expansion Valve Actuator Control Circuit Low)
B3A0D (A/C Refrigerant Expansion Valve Actuator Control Circuit High)
B1388 (A/C Refrigerant Expansion Valve Actuator "B" Control Circuit Low)
B1389 (A/C Refrigerant Expansion Valve Actuator "B" Control Circuit High)
U0111 (Lost Communication With Battery Energy Control Module "A")
P0C43 (Hybrid/EV Battery Refrigerant temperature Sensor "A" Circuit Range/Performance)
P0CD6 (Hybrid/EV Battery Refrigerant temperature Sensor "B" Circuit Range/Performance)
P1B84 (Hybrid/EV Battery Pressure Sensor Range/Performance)
Battery voltage 11 V or higher
Compressor actual speed 500 rpm or higher
Refrigerant cycle A/C Cooling or Dehumidification heating in parallel